• If you need to disconnect cables from the system board assembly, disengage all latches or
release tabs on cable connectors first. Failing to release the tab before removing the cables will
damage the cable sockets on the system board assembly. Any damage to the cable sockets
might require replacing the processor board or system I/O board.
• The connectors on your system board assembly might look different from those in the
illustration, but the removal procedure is the same.
1. Press the release tab to release the connector.
2. Disengage the connector from the cable socket.
Figure 76. Disconnecting cables from the system board assembly
Step 3.
Remove the front I/O module from the front chassis.
Figure 77. Front I/O module with the front operator
panel
a.
Remove the screw that secure the front I/O module.
ThinkSystem SR665 V3 User Guide
122
Figure 78. Front I/O module with the integrated
diagnostics panel