• Read
"Installation Guidelines" on page 47
work safely.
• Power off the server and peripheral devices and disconnect the power cords and all external cables. See
"Power off the server" on page
• Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static-
sensitive components in their static-protective packages until installation, and handling these devices with
an electrostatic-discharge wrist strap or other grounding system.
Procedure
Step 1.
Make preparation for the task.
a.
Access the Lenovo XClarity Controller; then, select Network in BMC Configuration and
disable Ethernet Port 2.
b.
If the server is installed in a rack, slide the server out on its rack slide rails to gain access to the
top cover, or remove the server from the rack. See
c.
Remove the top cover. See
d.
If your server comes with a riser 1 assembly, remove it first. See
assembly" on page
Step 2.
Disconnect the cable on the management NIC adapter.
Step 3.
Remove the management NIC adapter.
Figure 116. Removing the management NIC adapter
a.
Loosen the screw that secures the management NIC adapter.
b.
Press and hold the blue latch.
c.
Push the management NIC adapter by the latch out from the chassis.
After you finish
1. Install a replacement unit or a filler. See
2. If you are instructed to return the component or optional device, follow all packaging instructions, and
use any packaging materials for shipping that are supplied to you.
and
"Safety inspection checklist" on page 48
62.
"Remove the top cover" on page
232.
"Install the management NIC adapter" on page
"Remove the server from rack" on page
277.
"Remove a rear riser
.
Chapter 5
Hardware replacement procedures
to ensure that you
63.
158.
157