Download Print this page

Toro Greensmaster eFlex 1021 Service Manual page 137

Hide thumbs Also See for Greensmaster eFlex 1021:

Advertisement

Removing the Lithium-Ion Battery (continued)
Greensmaster
®
eFlex 1021
20248SL Rev C
g339409
1.
Negative (-) terminal
2.
Lithium-ion battery
3.
Positive (+) terminal
1. Ensure that the cutting-unit-drive lever is in the D
machine on a level surface, release the clutch bail, engage the service and
parking brake, rotate the key switch to O
the Operator's Manual.
2. Disconnect the battery pack; refer to
Lithium Battery Pack (page
3. Remove the four bolts that secures the battery cover to the battery mount.
Remove the battery cover from the machine.
4. Label and disconnect the negative (-) battery cable, positive (+) battery cable,
and battery interface harness from the lithium-ion battery; refer to
g339388
1.
Bolt (4 each)
2.
Washer (4 each)
3.
Lithium-ion battery
5. Remove the four nuts (item 5 in
secures the battery to the battery mount.
Figure 74
4.
Washer
5.
Lock washer
6.
Nut
FF
Disconnecting and Connecting the
5–3).
Figure 75
4.
Battery mount
5.
Nut (4 each)
Figure
75), bolts (1) and washers (2) that
Page 5–53
position, park the
ISENGAGE
, and remove the key; refer to
Electrical System: Service and Repairs
Figure
74.

Advertisement