Key Switch

Testing the Key Switch
Greensmaster
®
eFlex 1021
20248SL Rev C
g338795
1.
Screw (4 each)
2.
InfoCenter display
3.
Key
The key switch allows the machine operation to be turned on and off. The key
switch has 3 positions: O
TEC and is located on the InfoCenter mount
Check the key switch operation with the InfoCenter on the console. With the key
switch in the O
position, the InfoCenter should allow the information screen
N
to be displayed. If the InfoCenter operation suggests a damaged key switch,
proceed to the key switch testing below.
Note: If the eFlex machine is sitting idle for 5 minutes with the key switch in the
O
position, the machine will shut off.
N
Note: A damaged key switch may cause a #12 fault to be generated and
displayed on the InfoCenter. Refer to the
information on faults.
1. Ensure that the cutting-unit-drive lever is in the D
machine on a level surface, release the clutch bail, engage the service and
parking brake, rotate the key switch to O
the Operator's Manual.
2. Disconnect the battery pack; refer to
Lithium Battery Pack (page
3. Remove the InfoCenter mount from the handle to access the key switch;
refer to
Figure 58
4. Disconnect the wire harness electrical connector from the key switch.
Figure 58
4.
InfoCenter mount
5.
Key switch
6.
Handle
and O
. This switch is 1 of the several inputs for the
FF
N
(Figure
Faults Screen (page 5–15)
FF
Disconnecting and Connecting the
5–3).
Page 5–31
Electrical System: Testing the Electrical Components
58).
position, park the
ISENGAGE
, and remove the key; refer to
for