Testing the Key Switch (continued)
Electrical System: Testing the Electrical Components
g190999
5. With the use of a multimeter (ohms setting), test the switch functions to
determine if continuity exists between the various terminals for each switch
position. The switch terminals are marked as shown in
circuitry of the key switch is shown in the
Check the continuity between the switch terminals.
Circuit Logic Table
Switch Position
OFF
ON
START
6. Replace the key switch if necessary.
7. After you complete the testing, connect the wire harness electrical connector
to the key switch.
8. Install the InfoCenter mount to the handle; refer to
9. Connect the battery pack; refer to
Battery Pack (page
Figure 59
Circuit Logic Table (page
Disconnecting and Connecting the Lithium
5–3).
Page 5–32
Figure
59. The
5–32).
Circuits
None
B+C+F, D+E
A+B+C
Figure