Options - Samsung OfficeServ 500 Programming Manual

Hide thumbs Also See for OfficeServ 500:
Table of Contents

Advertisement

[834] H.323 OPTIONS
This MMC provides various VoIP support options. The options set in this MMC are set
system-wide.
No
Parameter
00
GATEWAY CALL ID
01
H.323 FAST SETUP
02
CALLER ID TYPE
06
TUNNELING
07
DEFAULT DIL NO
11
CODEC AUTO NEGO
14
SIGNAL PORT
17
SEND CLIP TABLE
18
INCOMING MODE
19
ALLOW GW CHECK
20
CLIR WITH NUMBER
© SAMSUNG Electronics Co., Ltd.
Description
This a up to 12 digits numeric entry that identifies
this system.
Enables or disables the H.323 Fast Start call setup
method.
This option controls the calling party identification
type. There are 3 possible selections :
0 GWID: Which shows the gateway call ID.
1 ANI: Which shows the calling station number
2 IP: Which shows the calling H.323 gateway IP
address.
Enables or disables the need for additional
channels using H.245 signaling. Tunneling allows
use of the H.245 signal channel with the Q.931
channel.
This allows programming of the default direct in
line number when digits are missing, or incorrect
on an inbound call.
Enables or disables Auto CODEC Negotiation
when the MGI is used as a H.323 gateway.
Indicate the port number for H.323 signaling and
sets a range of numbers allowed by firewall
equipment. The common and default IP path or
port used is 10000.
Refers to SEND CLI NUMBER(MMC323), which
provides calling party identification when using the
MGI as a H.323 gateway.
This provides station ID of the calling station. A
single digit value corresponding with the desired
table in MMC323 should be entered here. This is
only used when MMC405 value is null.
This option selects how incoming calls are routed
when the MGI is used as a H.323 gateway.
0 FOLLOW TRUNK RING: Follows MMC406
1 FOLLOW DID TRANS: Follows MMC714
2 FOLLOW INCOM DGT: Follows MMC724
When using a gatekeeper, this permits the H.323
gateway to check for gatekeeper presence.
When this option is set to ON, the CLIP number is
sent to the network even though the CLIP
restriction flag is set.
OfficeServ 500 Programming Guide
Default
1234
ENABLE
ANI
ENABLE
500
ON
-
1
FOLLOW
DID TRANS
DISABLE
DISABLE
2-369