2. Adjust float level.
A. Lightly push up float until it stops, then measure
clearance between needle valve and float lever.
Needle valve to
float lever clearance
B. If clearance is out of specification, adjust by
bending float lever as shown.
3. Install ball, weight and retainer in correct sequence
and location as shown.
4. Insert power needle (attached to piston valve assem­
bly) into power nozzle and install piston valve assembly
so diaphragm outer surface does not slip out from
groove.
Liquid Cooled Gas Engine
1.45 mm (.057 in.)
Page 3 – 76
Figure 145
Figure 146
Retainer
Weight
Ball
Figure 147
Figure 148