Failure Code [Ca2555] Grid Htr Relay Open Circuit Error - Komatsu PC200-8M0 Shop Manual

Table of Contents

Advertisement

SEN06134-00

Failure code [CA2555] Grid Htr Relay Open Circuit Error

Action
Failure code
level
L01
CA2555
q
Detail of failure
Open circuit is detected in drive circuit (primary circuit) of preheat relay.
Action of con-
q
None in particular
troller
q
Problem on
Intake air heater does not work in auto preheating (degraded starting performance at low temper-
machine
ature and emission of white smokes)
q
Temperature sensed by boost temperature sensor can be checked with monitoring function.
(Code: 18500)
q
Method of reproducing failure code: Turn starting switch to ON position (when boost temperature
Related infor-
is below -4 °C)
q
mation
Troubleshooting for this failure code covers circuit starting from engine controller to primary (coil)
side of preheater relay R18.
q
For troubleshooting related to heater relay and secondary side of preheater relay R18, see E-2 in
E-mode.
Cause
Defective wiring harness connec-
1
tor
2 Defective preheater relay R18
Open or short circuit in wiring har-
3
ness
4 Open circuit in wiring harness
5 Short circuit in wiring harness
6 Defective engine controller
52
40-302

Failure code [CA2555] Grid Htr Relay Open Circuit Error

Intake air Heater Relay Open Circuit Error
Failure
(Engine controller system)
Procedure, measuring location, criteria and remarks
See descriptions of wiring harness and connectors in "c: Electrical equipment"
in "Checks before troubleshooting" of "General information on troubleshoot-
ing", and check them.
1. Turn starting switch to OFF position.
2. Disconnect relay R18, and connect T-adapters to male side.
Between R18 (male) (1) and (2)
1. Turn starting switch to OFF position.
2. Replace relay R18 with another one.
3. Turn starting switch to ON position.
If this failure code disappears, original preheater relay R18 is defective.
1. Turn starting switch to OFF position.
2. Disconnect connector CE02, and connect T-adapters to female side.
Between CE02 (female) (40) and (42)
a Preheater relay R18 coil resistance
a If no failure is found by check on cause 3, this check is not required.
1. Turn starting switch to OFF position.
2. Disconnect connector CE02 and relay R18, and connect T-adapters to
each female side.
Between CE02 (female) (40) and R18 (female) (1)
Between R18 (female) (2) and CE02 (42)
1. Turn starting switch to OFF position.
2. Disconnect connector CE02 and relay R18, and connect T-adapters to
female side of CE02.
a Check with multimeter in continuity mode.
Between CE02 (female) (40) and each pin other
than (40)
If no failure is found by above checks, engine controller is defective. (Since
this is an internal defect, troubleshooting cannot be performed.)
302 Troubleshooting by failure code, Part 2
Resistance
Resistance
Resistance
Resistance
No continuity
(No sound is heard)
PC200, 200LC, 220, 220LC-8M0
200 to
400 z
200 to
400 z
Max. 1 z
Max. 1 z