SEN06128-00
4.
Clearing abnormality record
1)
While the "Electrical Systems" abnormality
record screen is displayed, press the
numeral input switches as follows.
q
Operation of switches (While pressing
[4], press the switches in order):
[4] + [1] o [ 2 ] o [ 3 ]
2)
Check that the screen is set in the clear
mode, and then clear the items one by
one or together by using the function
switches.
a If the screen is set in the clear mode,
icon [CLEAR] is indicated above [F2].
[F2]: Deletes all items
q
q
[F3]: Moves to lower item
q
[F4]: Moves to upper item
[F5]: Returns to the "Abnormality
q
Record" screen
q
[F6]: Deletes items one by one
a To clear items one by one: Select the
item to be cleared by using [F3] or
[F4] and press [F6].
a To clear all items together:
[F2], and all the items are cleared,
regardless of selection of the items.
a If [E] is displayed on the left of a fail-
ure code, the clearing operation is
accepted but the information is not
cleared.
32
30-102
3)
After the "Electrical Sys. Error Reset"
screen is displayed, press the function
switches.
q
q
a The following figure shows the screen
4)
If the screen to notify completion of clear-
ing is displayed and then the "Electrical
Systems" (clear mode) screen is dis-
played, the clearing of the abnormality
record is completed.
a After a while, the screen returns to
Press
102 Testing and adjusting, Part 2
Special functions of machine monitor
[F5]: Returns to "Electrical Systems
Abnormality Record" screen (delete
mode)
[F6]: Performs deletion
displayed when the items are cleared
one by one (which is a little different
from the screen displayed when all
the items are cleared together).
the "Electrical Systems" screen of
abnormality record.