Komatsu PC200-8M0 Shop Manual page 397

Table of Contents

Advertisement

101 Testing and adjusting, Part 1
Testing and adjusting oil pressure in pump LS control cir-
Adjusting
Adjusting LS valve
a If the LS differential pressure is abnormal,
adjust the LS valve according to the following
procedure.
q
(8): Front pump LS valve
(9): Rear pump LS valve
q
1.
While fixing adjustment screw (10), loosen
locknut (11).
2.
Turn adjustment screw (10) to adjust the differ-
ential pressure.
a If the adjustment screw is
Turned to the right, the differential
q
pressure is increased.
q
Turned to the left, the differential
pressure is decreased.
a Quantity of adjustment (LS differential
pressure) per turn of adjustment screw:
Approx. 1.1 MPa {Approx. 10.8 kg/cm
3.
While fixing adjustment screw (10), tighten
locknut (11).
3
Locknut: 49 to 68.6 Nm {5 to 7 kgm}
4.
After finishing adjustment, check again that the
LS differential pressure is normal according to
the above described measurement procedure.
PC200, 200LC, 220, 220LC-8M0
2
}
SEN06127-00
45
30-101

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc200lc-8m0Pc220-8m0Pc220lc-8m0