Komatsu PC200-8M0 Shop Manual page 466

Table of Contents

Advertisement

SEN06128-00
3.
Selecting low speed
After the "Low Speed" screen for setting is dis-
played, select a set value in the right column
by using the function switches.
q
Set value code:
speed at Low setting, see the table shown
below.
q
[F3]: Increases set value
q
[F4]: Decreases set value
q
[F6]: Confirms setting and returns to the
adjustment menu screen
a The 3-digit number in the left column do
not change since it is the code of this func-
tion.
a Relationship between set value and travel
speed at Low setting
Set value
Code
code
000
001
020
002
003
46
30-102
For the actual travel
Travel speed at Low
3.0 km/h
2.8 km/h
3.2 km/h
3.4 km/h
102 Testing and adjusting, Part 2
Special functions of machine monitor
Adjustment (Attachment Flow Adjustment)
The machine monitor allows for adjustment of vari-
ous items related to the machine with the machine
monitor.
The sub menu of "Attachment Flow Adjustment"
allows for fine adjustment of the oil flow to the
attachment during combined operation.
1.
Selecting the menu
Select "Adjustment" on the "Service Menu"
screen.
2.
Selecting sub menu
After the "Adjustment" screen is displayed,
select "Attachment Flow Adjustment" by using
t h e f u n c t i o n s w i t c h e s o r n u m e r a l i n p u t
switches.
a Select this sub menu as in the case of
selecting a menu on the "Service Menu"
screen.
3.
Selecting set value code for oil flow distribution
After the screen of "Attachment Flow Adjust-
ment" is displayed, select a set value in the
right column by using the function switches.
q
Set value code: For actual distribution of
oil flow, see the table shown below
q
[F3]: Increases set value
q
[F4]: Decreases set value
q
[F6]: Confirms setting and returns to the
adjustment menu screen
PC200, 200LC, 220, 220LC-8M0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc200lc-8m0Pc220-8m0Pc220lc-8m0