Komatsu PC200-8M0 Shop Manual page 282

Table of Contents

Advertisement

SEN06123-00
B mode and L mode
Mode
Partial output point
Mode
B
L
q
In B or L mode, engine output is controlled to a
constant level.
q
The controller controls the pump absorption
torque to decrease the engine speed while
keeping the engine torque at a constant level
along the equal engine horsepower curve.
The controller controls pump discharge (Q) so
q
that the engine torque can be kept at a con-
stant level along the equal engine horsepower
curve.
16
10-600
B
L
75%
70%
Matching point
80.9 kW/1,780 rpm
{108 HP/1,780 rpm}
73.6 kW/1,800 rpm
{99 HP/1,800 rpm}
2)
Function to control pump during travel
q
Traveling the machine in P or ATT mode
increases engine speed (N).
Traveling the machine in E or B mode leaves
q
the working mode unchanged, but raises the
pump absorption torque and engine speed (N)
to values same as those in P mode.
q
If the machine travels in L mode, the working
mode and engine speed (N) do not change,
but the pump absorption torque is increased.