SEN06127-00
Testing cab tipping stopper
a Check the cab tipping stopper according to the
following procedure.
1.
Remove the additional under cover at the rear
of the operator's cab. (Only for the machine
equipped with the reinforced type under cover)
2.
Check the tightening torque of the mounting
bolt (2) of the lock plate (1).
3
Bolt (2):
98 to 123 Nm {10 to 12.5 kgm}
[Reference]
q
The tightening torque of mounting bolt (4) of
cab tipping stopper (3) is different from that of
a common bolt 30 mm in diameter. Take care.
3
Bolt (4): 245 to 309 Nm {25 to 31.5 kgm}
60
30-101
101 Testing and adjusting, Part 1
Testing cab tipping stopper
PC200, 200LC, 220, 220LC-8M0