Failure Code [Dxa9Ka] Pc-Epc (R) Sol Open Circuit - Komatsu PC200-8M0 Shop Manual

Table of Contents

Advertisement

SEN06137-00

Failure code [DXA9KA] PC-EPC (R) Sol Open Circuit

Action
Failure code
level
L03
DXA9KA
q
Detail of failure
When PC-EPC (Rear) solenoid is driven, no current flows and open circuit is detected.
q
Action of con-
None in particular (Since no current flows, solenoid is not energized.)
q
troller
If cause of failure disappears, machine becomes normal by itself.
Problem on
q
If pump load increases, engine speed decreases largely and engine may stall.
machine
q
When solenoid and wiring harness are normal, engine can be prevented from stalling by setting
emergency pump drive switch to ON position.
Related infor-
q
Drive current of PC-EPC (R) solenoid can be checked with monitoring function.
mation
(Code: 01300 PC-EPC solenoid current (R))
q
Method of reproducing failure code: Turn starting switch to ON position.
Cause
Defective PC-EPC (R) solenoid
1
(Internal open circuit)
Defective emergency pump drive
2
switch
(Internal open circuit)
Open or short circuit in wiring har-
3
ness
Open circuit in wiring harness
4
(wire breakage or defective con-
tact of connector)
5 Defective pump controller
20
40-305
PC-EPC (Rear) Solenoid System Open Circuit
Failure
(Pump controller system)
Procedure, measuring location, criteria and remarks
1. Turn starting switch to OFF position.
2. Disconnect connector V12, and connect T-adapters to male side.
Between V12 (male) (1) and (2)
1. Turn starting switch to OFF position.
2. Disconnect connector S25 and connect T-adapters to male side.
Between S25 (male) (3)
and (2)
Between S25 (male) (6)
and (5)
1. Turn starting switch to OFF position.
2. Disconnect connector C02 and connect T-adapters to female side.
a Check that emergency pump drive switch is at normal position (lower side).
Between C02 (female) (96) and each of (115), (117)
and (120)
a If no failure is found in checks on cause 3, this check is not required.
1. Turn starting switch to OFF position.
2. Disconnect connectors C02, S25 and V12, and connect T-adapters to each
female side.
Between C02 (female) (96) and S25 (female) (3)
Between S25 (female) (2) and V12 (female) (1)
Between S25 (female) (6) and each of C02 (female)
(115), (117) and (120)
Between S25 (female) (5) and V12 (female) (2)
If no failure is found by above checks, pump controller is defective. (Since this
is an internal defect, troubleshooting cannot be performed.)
305 Troubleshooting by failure code, Part 5
Failure code [DXA9KA] PC-EPC (R) Sol Open Circuit
Switch position: Normal Resistance
Switch position: Emer-
gency
Switch position: Normal Resistance
Switch position: Emer-
gency
PC200, 200LC, 220, 220LC-8M0
3 to 14 z
Resistance
Max. 1 z
Resistance Min. 1 Mz
Max. 1 z
Resistance Min. 1 Mz
3 to 14 z
Resistance
Max. 1 z
Resistance
Max. 1 z
Resistance
Max. 1 z
Resistance
Max. 1 z
Resistance

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PC200-8M0 and is the answer not in the manual?

Questions and answers

mohammad ramezani
February 4, 2025

what is the NLC in komatsu

Clemence
February 19, 2025

My excavetor only starts with quick start

User image 67b591689cf69
Jesa
March 17, 2025

How to reset dashboard no ate 240

Jesa
March 17, 2025

How to reset dashboard komatsu 240

JUAN
March 28, 2025

A QUE SE REFIERE EL CODIGO DA22KK Y QUE LO ORIGINA

1 comments:
Mr. Anderson
March 28, 2025

The code DA22KK for the Komatsu PC200-8M0 refers to a "Pump Solenoid Power Low Error." It indicates that the power supply voltage of the controller for driving solenoids is below 20V. When this error is active, the system stops generating failure codes for all solenoid systems. The machine will not operate properly because no solenoid valve is energized correctly. If the cause is resolved, the machine returns to normal automatically. Possible causes include a defective fusible link or fuse, which may indicate a ground fault.

This answer is automatically generated

This manual is also suitable for:

Pc200lc-8m0Pc220-8m0Pc220lc-8m0

Table of Contents