SEN06128-00
4.
Performing monitoring
After the "Monitoring" screen for execution is
displayed, perform the necessary operation of
the machine and check the monitoring informa-
tion.
a Monitoring information is indicated by
value, ON/OFF, or special display.
a The unit of display can be selected in SI
unit, metric unit, or inch unit with the
Default function in the service mode.
5.
Holding monitoring information
The monitoring information can be held and
released with the function switches.
[F4]: Selects hold or its releasing
q
(If hold is selected, a diagonal line is dis-
played on the HOLD portion)
[F5]:
Returns the display to monitoring
q
selection menu screen
24
30-102
102 Testing and adjusting, Part 2
Special functions of machine monitor
6.
Changing machine setting mode during moni-
toring
To change the setting of the working mode,
travel speed, or auto-deceleration during moni-
toring, operate the corresponding switch under
the current condition to turn on the applicable
mode.
a If the setting is changed during monitoring,
the new setting is held even after the
screen returns to the standard screen
after monitoring is finished.
a If the working mode is changed to breaker
mode [B], the screen to confirm the change of
the setting is displayed as in changing the
working mode on the standard screen.
PC200, 200LC, 220, 220LC-8M0