Failure Code [Dhsbma] Swing Lh Ppc Press Sensor Abnormality - Komatsu PC200-8M0 Shop Manual

Table of Contents

Advertisement

SEN06136-00

Failure code [DHSBMA] Swing LH PPC Press Sensor Abnormality

Action
Failure code
level
L01
DHSBMA
q
Detail of failure
Signal voltage of swing LEFT PPC pressure sensor is below 0.3 V or above 4.5 V.
Action of con-
q
Controls machine taking it that swing LEFT PPC pressure is 0 MPa {0 kg/cm
troller
q
If cause of failure disappears, machine becomes normal by itself.
q
Problem on
Automatic deceleration does not cancel.
machine
q
Controllability of swing LEFT deteriorates.
a If 5 V circuit (3) and ground circuit (1) of pressure sensor are connected inversely, pressure sensor
will be broken. Accordingly, take extreme care when checking.
q
As T-adapter for pump controller connector is "socket-type box", operating voltage cannot be mea-
Related infor-
sured at pump controller connector.
mation
q
Swing LEFT PPC pressure can be checked with monitoring function.
(Code 09001: Swing LEFT PPC pressure)
q
Method of reproducing failure code: Turn starting switch to ON position or start engine.
Cause
Defective 5V sensor power supply
1
1 system
Defective swing left PPC pressure
2
sensor
(internal defect)
Open circuit in wiring harness
3
(wire breakage or defective con-
tact of connector)
Ground fault in wiring harness
4
(contact with ground circuit)
14
40-304
Failure code [DHSBMA] Swing LH PPC Press Sensor Abnormality
Swing Left PPC Pressure Sensor Abnormality
Failure
(Pump controller system)
Procedure, measuring location, criteria and remarks
If failure code [DA25KP] is also displayed, perform troubleshooting for it first.
1. Turn starting switch to OFF position.
2. Disconnect connector P03 and connect T-adapters to female side.
3. Turn starting switch to ON position.
a If power supply voltage is abnormal, proceed to check on cause 3.
Between P03 (female) (3) and (1)
1. Turn starting switch to OFF position.
2. Insert T-adapters into connector P03.
3. Turn starting switch to ON position.
Between P03 (2) and (1)
a If power supply voltage is normal and sensor output voltage is abnormal, it
is difficult to judge whether cause of failure is defective sensor, ground fault
or hot short circuit in wiring harness. Check as below.
1. Turn starting switch to OFF position.
2. Replace connector P03 with connector of other PPC pressure sensor.
3. Turn starting switch to ON position and display "Abnormality Record"
screen of electrical system on machine monitor.
4. If E-mark for this failure code is not displayed, swing LEFT PPC pressure
sensor is defective.
a After finishing test, restore connectors.
1. Turn starting switch to OFF position.
2. Disconnect connectors C01 and P03, and connect T-adapters to each
female side.
a If power supply voltage measured in check on
cause 1 is normal, this check is not required.
Between C01 (female) (18) and P03 (female) (1)
Between C01 (female) (16) and P03 (female) (2)
a If power supply voltage measured in check on
cause 1 is normal, this check is not required.
Between C01 (female) (9) and P03 (female) (3)
1. Turn starting switch to OFF position.
2. Disconnect connectors C01 and P03, and connect T-adapters to either
female side.
Between ground and C01 (female) (16) or P03
(female) (2)
304 Troubleshooting by failure code, Part 4
2
}.
Power sup-
Voltage
ply
Sensor out-
Voltage
put
Resistance
Resistance
Resistance
Resistance Min. 1 Mz
PC200, 200LC, 220, 220LC-8M0
4.5 to 5.5 V
0.5 to 4.5 V
Max. 1 z
Max. 1 z
Max. 1 z