SEN06135-00
Failure code [DHPBMA] R Pump Press Sensor Abnormality
Action
Failure code
level
L01
DHPAMA
q
Detail of failure
Signal voltage of rear pump pressure sensor circuit is below 0.3 V or above 4.5 V.
Action of con-
q
Controls machine taking it that rear pump pressure is 0 MPa {0 kg/cm
troller
q
If cause of failure disappears, machine becomes normal by itself.
q
Problem on
Automatic travel speed selector function does not work.
q
machine
Straight travel performance or steering performance lowers.
a If 5 V circuit (3) and ground circuit (1) of pressure sensor are connected inversely, pressure sensor
will be broken. Accordingly, take extreme care when checking.
q
As T-adapter for pump controller connector is "socket-type box", operating voltage cannot be mea-
Related infor-
sured at pump controller connector.
mation
q
Rear pump pressure can be checked with monitoring function.
(Code: 01101 R pump pressure)
q
Method of reproducing failure code: Turn starting switch to ON position or start engine.
Cause
Defective 5V sensor power supply
1
1 system
Defective rear pump pressure sen-
2
sor (internal defect)
Open circuit in wiring harness
3
(wire breakage or defective con-
tact of connector)
Ground fault in wiring harness
4
(contact with ground circuit)
46
40-303
Failure code [DHPBMA] R Pump Press Sensor Abnormality
Rear Pump Pressure Sensor Abnormality
Failure
(Pump controller system)
Procedure, measuring location, criteria and remarks
If failure code [DA25KP] is also displayed, perform troubleshooting for it first.
1. Turn starting switch to OFF position.
2. Disconnect connector P26, and connect T-adapters to female side.
3. Turn starting switch to ON position.
a If power supply voltage is abnormal, proceed to check on cause 3.
Between P26 (female) (3) and (1)
1. Turn starting switch to OFF position.
2. Connect T-adapters to connector P26.
3. Turn starting switch to ON position.
Between P26 (2) and (1)
a If power supply voltage is normal and sensor output voltage is abnormal, it
is difficult to judge whether cause of failure is defective sensor, ground fault
or hot short circuit in wiring harness. Check as below.
1. Turn starting switch to OFF position.
2. Replace connector P26 with connector P25 of front pump PPC pressure
sensor.
3. Turn starting switch to ON position and display "Abnormality Record"
screen of electrical system on machine monitor.
4. If E mark is not displayed for this failure code, rear pump pressure sensor
is defective.
a After finishing test, restore connectors.
1. Turn starting switch to OFF position.
2. Disconnect connectors C01 and P26, and connect T-adapters to each
female side.
a If power supply voltage measured in check on
cause 1 is normal, this check is not required.
Between C01 (female) (18) and P26 (female) (1)
Between C01 (female) (68) and P26 (female) (2)
a If power supply voltage measured in check on
cause 1 is normal, this check is not required.
Between C01 (female) (9) and P26 (female) (3)
1. Turn starting switch to OFF position.
2. Disconnect connectors C01 and P26, and connect T-adapters to either
female side.
Between C01 (female) (68) or P26 (female) (2) and
ground
303 Troubleshooting by failure code, Part 3
2
}.
Power sup-
Voltage
ply
Sensor out-
Voltage
put
Resistance
Resistance
Resistance
Resistance Min. 1 Mz
PC200, 200LC, 220, 220LC-8M0
4.5 to 5.5 V
0.5 to 4.5 V
Max. 1 z
Max. 1 z
Max. 1 z
Need help?
Do you have a question about the PC200-8M0 and is the answer not in the manual?
Questions and answers
what is the NLC in komatsu
My excavetor only starts with quick start
How to reset dashboard no ate 240
How to reset dashboard komatsu 240
A QUE SE REFIERE EL CODIGO DA22KK Y QUE LO ORIGINA
The code DA22KK for the Komatsu PC200-8M0 refers to a "Pump Solenoid Power Low Error." It indicates that the power supply voltage of the controller for driving solenoids is below 20V. When this error is active, the system stops generating failure codes for all solenoid systems. The machine will not operate properly because no solenoid valve is energized correctly. If the cause is resolved, the machine returns to normal automatically. Possible causes include a defective fusible link or fuse, which may indicate a ground fault.
This answer is automatically generated