Displays On Machine Monitor Are Different From Those For Actual Machine - Komatsu PC200-8M0 Shop Manual

Table of Contents

Advertisement

SEN06138-00
E-10 Displays on machine monitor are different from those for actual
machine
q
Failure
Related information
q
PC200-8M0, PC200LC-8M0
Cause
1 Defective model code signal
2 Defective machine monitor
q
PC220-8M0, PC220LC-8M0
Cause
1 Defective model code signal
2 Defective machine monitor
30
40-400
E-10 Displays on machine monitor are different from those for actual machine

Displays on machine monitor are different from those for actual machine

a Turn starting switch to ON position and perform troubleshooting (with moni-
toring function).
Monitoring code
If display on monitor is incorrect, perform troubleshooting for failure code
[DA29KQ].
If no failure is found by check on cause 1, machine monitor is defective. (Since
this is an internal defect, troubleshooting cannot be performed.)
a Turn starting switch to ON position and perform troubleshooting (with moni-
toring function).
Monitoring code
If display on monitor is incorrect, perform troubleshooting for failure code
[DA29KQ].
If no failure is found by check on cause 1, machine monitor is defective. (Since
this is an internal defect, troubleshooting cannot be performed.)
400 Troubleshooting of electrical system (E-mode)
Procedure, measuring location, criteria and remarks
00201 Switch Input
2
Procedure, measuring location, criteria and remarks
00201 Switch Input
2
Model selection 1
= OFF
Model selection 2
= OFF
Model selection 3
Monitoring display
= ON
Model selection 4
= OFF
Model selection 5
= OFF
Model selection 1
= ON
Model selection 2
= OFF
Model selection 3
Monitoring display
= ON
Model selection 4
= OFF
Model selection 5
= OFF
PC200, 200LC, 220, 220LC-8M0