GE N60 Instruction Manual page 433

Network stability and synchrophasor measurement system
Hide thumbs Also See for N60:
Table of Contents

Advertisement

APPENDIX A: FLEXANALOG OPERANDS
Address
FlexAnalog name
9840
PMU 6 Vx Mag
9842
PMU 6 Vx Angle
9843
PMU 6 V1 Mag
9845
PMU 6 V1 Angle
9846
PMU 6 V2 Mag
9848
PMU 6 V2 Angle
9849
PMU 6 V0 Mag
9851
PMU 6 V0 Angle
9852
PMU 6 Ia Mag
9854
PMU 6 Ia Angle
9855
PMU 6 Ib Mag
9857
PMU 6 Ib Angle
9858
PMU 6 Ic Mag
9860
PMU 6 Ic Angle
9861
PMU 6 Ig Mag
9863
PMU 6 Ig Angle
9864
PMU 6 I1 Mag
9866
PMU 6 I1 Angle
9867
PMU 6 I2 Mag
9869
PMU 6 I2 Angle
9870
PMU 6 I0 Mag
9872
PMU 6 I0 Angle
9873
PMU 6 Freq
9875
PMU 6 df dt
9876
PMU 6 Conf Ch
12306
Oscill Num Triggers
13504
DCmA Inputs 1 Value
13506
DCmA Inputs 2 Value
13508
DCmA Inputs 3 Value
13510
DCmA Inputs 4 Value
13512
DCmA Inputs 5 Value
13514
DCmA Inputs 6 Value
13516
DCmA Inputs 7 Value
13518
DCmA Inputs 8 Value
13520
DCmA Inputs 9 Value
13522
DCmA Inputs 10 Value
13524
DCmA Inputs 11 Value
13526
DCmA Inputs 12 Value
13528
DCmA Inputs 13 Value
13530
DCmA Inputs 14 Value
13532
DCmA Inputs 15 Value
13534
DCmA Inputs 16 Value
13536
DCmA Inputs 17 Value
13538
DCmA Inputs 18 Value
13540
DCmA Inputs 19 Value
13542
DCmA Inputs 20 Value
13544
DCmA Inputs 21 Value
N60 NETWORK STABILITY AND SYNCHROPHASOR MEASUREMENT SYSTEM – INSTRUCTION MANUAL
Units
Description
Volts
Phasor measurement unit 6 auxiliary voltage magnitude
Degrees
Phasor measurement unit 6 auxiliary voltage angle
Volts
Phasor measurement unit 6 positive-sequence voltage magnitude
Degrees
Phasor measurement unit 6 positive-sequence voltage angle
Volts
Phasor measurement unit 6 negative-sequence voltage magnitude
Degrees
Phasor measurement unit 6 negative-sequence voltage angle
Volts
Phasor measurement unit 6 zero-sequence voltage magnitude
Degrees
Phasor measurement unit 6 zero-sequence voltage angle
Amps
Phasor measurement unit 6 phase A current magnitude
Degrees
Phasor measurement unit 6 phase A current angle
Amps
Phasor measurement unit 6 phase B current magnitude
Degrees
Phasor measurement unit 6 phase B current angle
Amps
Phasor measurement unit 6 phase C current magnitude
Degrees
Phasor measurement unit 6 phase C current angle
Amps
Phasor measurement unit 6 ground current magnitude
Degrees
Phasor measurement unit 6 ground current angle
Amps
Phasor measurement unit 6 positive-sequence current magnitude
Degrees
Phasor measurement unit 6 positive-sequence current angle
Amps
Phasor measurement unit 6 negative-sequence current magnitude
Degrees
Phasor measurement unit 6 negative-sequence current angle
Amps
Phasor measurement unit 6 zero-sequence current magnitude
Degrees
Phasor measurement unit 6 zero-sequence current angle
Hz
Phasor measurement unit 6 frequency
Hz/s
Phasor measurement unit 6 rate of change of frequency
---
Phasor measurement unit 6 configuration change counter
---
Oscillography number of triggers
mA
DCmA input 1 actual value
mA
DCmA input 2 actual value
mA
DCmA input 3 actual value
mA
DCmA input 4 actual value
mA
DCmA input 5 actual value
mA
DCmA input 6 actual value
mA
DCmA input 7 actual value
mA
DCmA input 8 actual value
mA
DCmA input 9 actual value
mA
DCmA input 10 actual value
mA
DCmA input 11 actual value
mA
DCmA input 12 actual value
mA
DCmA input 13 actual value
mA
DCmA input 14 actual value
mA
DCmA input 15 actual value
mA
DCmA input 16 actual value
mA
DCmA input 17 actual value
mA
DCmA input 18 actual value
mA
DCmA input 19 actual value
mA
DCmA input 20 actual value
mA
DCmA input 21 actual value
FLEXANALOG ITEMS
A
A-15