SPECIFICATIONS
PARALLEL REDUNDANCY PROTOCOL (PRP)
(IEC 62439-3 CLAUSE 4, 2012)
Ethernet ports used:
Networks supported:
OTHER
TFTP, SFTP, HTTP, IEC 60870-5-104, Ethernet Global Data (EGD), IEEE C37.118
2

2.4.9 Inter-relay communications

SHIELDED TWISTED-PAIR INTERFACE OPTIONS
Interface type
RS422
G.703
RS422 distance is based on transmitter power and does not take into consideration the clock source provided
by the user.
NOTE
LINK POWER BUDGET
Emitter, fiber type
820 nm LED, Multimode
1300 nm LED, Multimode
1300 nm ELED, Single mode
1300 nm Laser, Single mode
1550 nm Laser, Single mode
These power budgets are calculated from the manufacturer's worst-case transmitter power and worst case
receiver sensitivity.
NOTE
The power budgets for the 1300 nm ELED are calculated from the manufacturer's transmitter power and
receiver sensitivity at ambient temperature. At extreme temperatures these values deviate based on
component tolerance. On average, the output power decreases as the temperature is increased by a factor
1 dB / 5 °C.
MAXIMUM OPTICAL INPUT POWER
Emitter, fiber type
820 nm LED, Multimode
1300 nm LED, Multimode
1300 nm ELED, Single mode
1300 nm Laser, Single mode
1550 nm Laser, Single mode
2-24
2 and 3
10/100 Mb Ethernet
Typical distance
1200 m
100 m
Transmit
Received
power
sensitivity
–20 dBm
–30 dBm
–21 dBm
–30 dBm
–23 dBm
–32 dBm
–1 dBm
–30 dBm
+5 dBm
–30 dBm
Maximum optical
input power
–7.6 dBm
–11 dBm
–14 dBm
–14 dBm
–14 dBm
N60 NETWORK STABILITY AND SYNCHROPHASOR MEASUREMENT SYSTEM – INSTRUCTION MANUAL
Power
budget
10 dB
9 dB
9 dB
29 dB
35 dB