System Alarm Assignments - Samsung OfficeServ 7000 Series Programming Manual

Call server
Hide thumbs Also See for OfficeServ 7000 Series:
Table of Contents

Advertisement

[852] SYSTEM ALARM ASSIGNMENTS

This MMC allows the assignment of system alarms to ring and display on stations that
have an Alarm key assigned. The Alarm key is assigned in MMC 722 (Station Key
Programming). Alarm key programming is tenant wide (tenants 1 and 2). Alarms not
programmed to report to the system Alarm key will still be retained in the maintenance
alarm buffer for Alarm Reporting (MMC 851). The alarm buffer holds up to 100 alarms on
a First In-First Out (FIFO) basis. Pressing the Alarm key will silence the audible alarm
until another alarm is generated by the system. Alarm conditions that have multiple causes
(e.g., PRI errors and synchronization loss) will print all associated alarm information if an
SIO port is programmed as an ALARM port. The specific fault alarm data can be displayed
via MMC 851, System Alarm Reporting.
Alarm Notification
Alarm Notification Off/On (0/1) determines if the alarm provides a visual and
audible notification to the System Alarm key station (s). Pressing the System
Alarm key and the release key will silence the audible alarm only at the station
that pressed the System Alarm key and the release key. See alarm displays table
for assignments.
Alarm Code Definitions:
No
Code
-
MJA--
01
MJA01
02
MJA02
03
MJA03
04
MJA04
05
MJA05
06
MJA06
© SAMSUNG Electronics Co., Ltd.
OfficeServ 7000 Series Call Server Programming Manual
Alarm Name
MCP2 Error
System Fault
Power On
MP card restart process has been executed via power on
Restart
restart. (POR)
Button Restart
MP card restart process has been executed via button
reset.
MMC Reset
The system RAM has been cleared via manual
programming (PCMMC or KMMC) resulting in a system
reset.
MCP Reset
The MP card has software exception error.
Alarm data = Reason
- BUS ERR: Restart Bus Error
- ADDR.ERR: Restart Address Error
- ILLEGAL: Restart Illegal OPcode
- ZERO DIVID: Restart Zero Divide
- PRIVILEGE: Restart Privilege Violation
- ENDL LOOP: Restart Endless Loop
LCP Restart
The LP card has reset
Alarm data = Cabinet (1, 2 or 3)
PCM Switching
A fault has occurred in the Switching Control
Alarm data = MCP BASE, ESM: 1, ESM: 2 or ESM: 3