How to select the monitored signals
Step
Action
1.
You can select which signals are monitored in the Output mode and how
they are displayed with group
63
for detailed instructions on changing parameter values.
By default, the display shows three signals. The particular default signals
depend on the value of parameter
whose default value of parameter
1 (VECTOR:SPEED), the default for signal 1 is
0103
OUTPUT FREQ. The defaults for signals 2 and 3 are always
CURRENT and
To change the default signals, select up to three signals from group
OPERATING DATA
Signal 1: Change the value of parameter
index of the signal parameter in group
the parameter without the leading zero), e.g. 105 means parameter
TORQUE. Value 100 means that no signal is displayed.
Repeat for signals 2
PARAM). For example, if
only the signal specified by
parameters are set to 0, i.e. no signals are selected for monitoring, the
panel displays text "n.A".
2.
Specify the decimal point location, or use the decimal point location and
unit of the source signal [setting (9 (DIRECT)]. Bar graphs are not available
for Basic Operation Panel. For details, see parameter 3404.
Signal 1: parameter
Signal 2: parameter
Signal 3: parameter
3.
Select the units to be displayed for the signals. This has no effect if
parameter
3404/3411/3418
parameter 3405.
Signal 1: parameter
Signal 2: parameter
Signal 3: parameter
4.
Select the scalings for the signals by specifying the minimum and
maximum display values. This has no effect if parameter
set to 9 (DIRECT). For details, see parameters
Signal 1: parameters
Signal 2: parameters
Signal 3: parameters
Control panels
34 PANEL DISPLAY
9902
APPLIC MACRO: For macros
9904
MOTOR CTRL MODE is
0105
TORQUE, respectively.
to be shown.
01 OPERATING DATA
(3408
SIGNAL2 PARAM) and 3
3401
= 0 and
3415
3408
appears in the display. If all three
3404
OUTPUT1 DSP FORM
3411
OUTPUT2 DSP FORM
3418
OUTPUT3 DSP FORM.
is set to 9 (DIRECT). For details, see
3405
OUTPUT1 UNIT
3412
OUTPUT2 UNIT
3419
OUTPUT3 UNIT.
3406
OUTPUT1 MIN and
3413
OUTPUT2 MIN and
3420
OUTPUT3 MIN and
parameters. See page
0102
SPEED, otherwise
3401
SIGNAL1 PARAM to the
(= number of
(3415
SIGNAL3
= 0, browsing is disabled and
3404/3411/3418
3406
and 3407.
3407
OUTPUT1 MAX
3414
OUTPUT2 MAX
3421
OUTPUT3 MAX.
Display
LOC
LOC
LOC
0104
01
0105
LOC
LOC
LOC
is
5000
LOC
103
PAR
SET
FWD
104
PAR
SET
FWD
105
PAR
SET
FWD
9
PAR
SET
FWD
3
PAR
SET
FWD
00
.
Hz
PAR
SET
FWD
.
Hz
PAR
SET
FWD