Parameters – short form list
Index
Name/Selection
3002
PANEL COMM ERR
3003
EXTERNAL FAULT 1
3004
EXTERNAL FAULT 2
3005
MOT THERM PROT
3006
MOT THERM TIME
3007
MOT LOAD CURVE
3008
ZERO SPEED LOAD
3009
BREAK POINT FREQ
3010
STALL FUNCTION
3011
STALL FREQUENCY
3012
STALL TIME
3013
UNDERLOAD FUNC
3014
UNDERLOAD TIME
3015
UNDERLOAD CURVE
3016
SUPPLY PHASE
3017
EARTH FAULT
3018
COMM FAULT FUNC
3019
COMM FAULT TIME
3021
AI1 FAULT LIMIT
3022
AI2 FAULT LIMIT
3023
WIRING FAULT
31
AUTOMATIC RESET
3101
NR OF TRIALS
3102
TRIAL TIME
3103
DELAY TIME
3104
AR OVERCURRENT
3105
AR OVERVOLTAGE
3106
AR UNDERVOLTAGE
3107
AR AI<MIN
3108
AR EXTERNAL FLT
32
SUPERVISION
3201
SUPERV 1 PARAM
3202
SUPERV 1 LIM LO
3203
SUPERV 1 LIM HI
3204
SUPERV 2 PARAM
3205
SUPERV 2 LIM LO
Actual signals and parameters
Description
Selects how the drive reacts to a control panel communication
break.
Selects an interface for an external fault 1 signal.
Selects an interface for an external fault 2 signal.
Selects how the drive reacts when the motor overtemperature is
detected.
Defines the thermal time constant for the motor thermal model.
Defines the load curve together with parameters 3008 ZERO
SPEED LOAD and 3009 BREAK POINT FREQ.
Defines the load curve together with parameters 3007 MOT
LOAD CURVE and 3009 BREAK POINT FREQ.
Defines the load curve together with parameters 3007 MOT
LOAD CURVE and 3008 ZERO SPEED LOAD.
Selects how the drive reacts to a motor stall condition.
Defines the frequency limit for the stall function.
Defines the time for the stall function.
Selects how the drive reacts to underload.
Defines the time limit for the underload function.
Selects the load curve for the underload function.
Selects how the drive reacts to supply phase loss, i.e. when DC
voltage ripple is excessive.
Selects how the drive reacts when an earth (ground) fault is
detected in the motor or the motor cable.
Selects how the drive reacts in a fieldbus communication break.
Defines the time delay for the fieldbus communication break
supervision.
Defines a fault level for analog input AI1.
Defines a fault level for analog input AI2.
Selects how the drive reacts when incorrect input power and
motor cable connection is detected.
Automatic fault reset.
Defines the number of automatic fault resets the drive performs
within the time defined by parameter 3102 TRIAL TIME.
Defines the time for the automatic fault reset function.
Defines the time that the drive will wait after a fault before
attempting an automatic reset.
Activates/deactivates the automatic reset for the overcurrent
fault.
Activates/deactivates the automatic reset for the intermediate
link overvoltage fault.
Activates/deactivates the automatic reset for the intermediate
link undervoltage fault.
Activates/deactivates the automatic reset for fault AI<MIN.
Activates/deactivates the automatic reset for the EXTERNAL
FAULT 1/2.
Signal supervision. Supervision status can be monitored with
relay or transistor output.
Selects the first supervised signal.
Defines the low limit for the first supervised signal selected by
parameter 3201 SUPERV 1 PARAM.
Defines the high limit for the first supervised signal selected by
parameter 3201 SUPERV 1 PARAM.
Selects the second supervised signal.
Defines the low limit for the second supervised signal selected
by parameter 3204 SUPERV 2 PARAM.
Def
Custom
FAULT
NOT SEL
NOT SEL
FAULT
500
100
70
35
NOT SEL
20
20
NOT SEL
20
1
FAULT
ENABLE
NOT SEL
3
MINIMUM AI1.
MINIMUM AI2.
ENABLE
0
30
0
DISABLE
DISABLE
DISABLE
DISABLE
DISABLE
103
-
-
104
-