Parameters – complete descriptions
Index Name/Selection
COMM
DI1(INV)
DI2(INV)
DI3(INV)
DI4(INV)
DI5(INV)
1609
START ENABLE 2
1610
DISPLAY ALARMS
NO
YES
1611
PARAMETER VIEW
DEFAULT
FLASHDROP
18 FREQ IN & TRAN
OUT
1801
FREQ INPUT MIN
0...10000 Hz
1802
FREQ INPUT MAX
0...10000 Hz
1803
FILTER FREQ IN
0.0...10.0 s
1804
TO MODE
DIGITAL
Description
Fieldbus interface as the source for the inverted Start Enable (Start Disable)
signal, i.e. control word
0302
2). The control word is sent by the fieldbus controller via the fieldbus adapter
or embedded fieldbus (modbus) to the drive. For the control word bits, see
section
DCU communication profile
Note: This setting applies only for the DCU profile!
External signal required through inverted digital input DI1. 0 = Start Enable.
If Start Enable signal is switched off, the drive will not start or it coasts to stop
if it is running and alarm START ENABLE 1 MISSING is activated.
See selection DI1(INV).
See selection DI1(INV).
See selection DI1(INV).
See selection DI1(INV).
Selects the source for the Start Enable 2 signal. See parameter
ENABLE 1.
See parameter 1608.
Activates/deactivates alarms OVERCURRENT (2001), OVERVOLTAGE
(2002), UNDERVOLTAGE (2003) and DEVICE OVERTEMP (2009). For
more information see chapter
Alarms are inactive.
Alarms are active.
Selects the parameter view, i.e which parameters are shown.
Note: This parameter is visible only when it is activated by the optional
FlashDrop device. FlashDrop is designed for fast copying of parameters to
unpowered drives. It allows for easy customisation of the parameter list, e.g.
selected parameters can be hidden. For more information, see MFDT-01
FlashDrop User's Manual [3AFE68591074 (English)].
FlashDrop parameter values are activated by setting parameter
APPLIC MACRO to LOAD FD SET.
Complete long and short parameter lists
FlashDrop parameter list. Does not include short parameter list. Parameters
which are hidden by the FlashDrop device are not visible.
Frequency input and transistor output signal processing.
Defines the minimum input value when DI5 is used as a frequency input. See
section
Frequency input
on page 105.
Minimum frequency
Defines the maximum input value when DI5 is used as a frequency input.
See section
Frequency input
Maximum frequency
Defines the filter time constant for frequency input, i.e the time within 63% of
a step change is reached. See section
Filter time constant
Selects the operation mode for the transistor output TO. See section
Transistor output
on page 105.
Transistor output is used as a digital output DO.
FB CMD WORD 2 bit 18 (bit 19 for Start Enable
on page 262.
Fault
tracing.
on page 105.
Frequency input
Def, FbEq
7
-1
-2
-3
-4
-5
1608
START
NOT SEL
NO
0
1
DEFAULT
9902
0
1
0
1 = 1 Hz
1000
1 = 1 Hz
0.1
on page 105.
1 = 0.1 s
DIGITAL
0
Actual signals and parameters
175