ABB ACS350 User Manual page 157

Hide thumbs Also See for ACS350:
Table of Contents

Advertisement

Parameters – short form list
Index
Name/Selection
5127
FBA PAR REFRESH
52
PANEL COMM
5201
STATION ID
5202
BAUD RATE
5203
PARITY
5204
OK MESSAGES
5205
PARITY ERRORS
5206
FRAME ERRORS
5207
BUFFER OVERRUNS
5208
CRC ERRORS
53
EFB PROTOCOL
5302
EFB STATION ID
5303
EFB BAUD RATE
5304
EFB PARITY
5305
EFB CTRL PROFILE
5306
EFB OK MESSAGES
5307
EFB CRC ERRORS
5310
EFB PAR 10
5311
EFB PAR 11
5312
EFB PAR 12
5313
EFB PAR 13
5314
EFB PAR 14
5315
EFB PAR 15
5316
EFB PAR 16
5317
EFB PAR 17
5318
EFB PAR 18
5319
EFB PAR 19
5320
EFB PAR 20
54
FBA DATA IN
5401
FBA DATA IN 1
5402
FBA DATA IN 2
....
...
5410
FBA DATA IN 10
55
FBA DATA OUT
5501
FBA DATA OUT 1
5502
FBA DATA OUT 2
...
...
5510
FBA DATA OUT 10
84
SEQUENCE PROG
8401
SEQ PROG ENABLE
8402
SEQ PROG START
Description
Validates any changed adapter module configuration parameter
settings.
Communication settings for the control panel port on the drive
Defines the address of the drive.
Defines the transfer rate of the link.
Defines the use of parity and stop bit(s).
Number of valid messages received by the drive.
Number of characters with a parity error received from the
Modbus link.
Number of characters with a framing error received by the
Modbus link.
Number of characters which overflow the buffer, i.e. number of
characters which exceed the maximum message length, 128
bytes.
Number of messages with an CRC (cyclic redundancy check)
error received by the drive.
Embedded fieldbus link settings.
Defines the address of the device.
Defines the transfer rate of the link.
Defines the use of parity and stop bit(s) and the data length.
Selects the communication profile.
Number of valid messages received by the drive.
Number of messages with an CRC (cyclic redundancy check)
error received by the drive.
Selects an actual value to be mapped to Modbus register 40005.
Selects an actual value to be mapped to Modbus register 40006.
Selects an actual value to be mapped to Modbus register 40007.
Selects an actual value to be mapped to Modbus register 40008.
Selects an actual value to be mapped to Modbus register 40009.
Selects an actual value to be mapped to Modbus register 40010.
Selects an actual value to be mapped to Modbus register 40011.
Selects an actual value to be mapped to Modbus register 40012.
Reserved
ABB Drives profile (ABB DRV LIM or ABB DRV FULL) Control
Word. Read only copy of the Fieldbus Control Word.
ABB Drives profile (ABB DRV LIM or ABB DRV FULL) Status
Word. Read only copy of the Fieldbus Status Word.
Data from drive to fieldbus controlle.
Selects data to be transferred from the drive to the fieldbus
controller.
See 5401 FBA DATA IN 1.
...
See 5401 FBA DATA IN 1.
Data from fieldbus controller to drive.
Selects data to be transferred from the fieldbus controller to the
drive.
See 5501 FBA DATA OUT 1.
...
See 5501 FBA DATA OUT 1.
Sequence programming.
Enables sequence programming.
Selects the source for the sequence programming activation
signal.
Def
Custom
1
39242
8 NONE 1
0
0
0
0
0
1
39242
8 NONE 1
ABB DRV LIM
0
0
0
0
0
0
0
0
0
0
0
0x0000
0x0000
DISABLED
NOT SEL
Actual signals and parameters