Delivery check

Check that there are no signs of damage. Notify the shipper immediately if damaged
components are found.
Before attempting installation and operation, check the information on the type
designation label of the drive to verify that the drive is of the correct type. The type
designation label is attached to the left side of the drive. An example label and
explanation of the label contents are shown below.
2
IP20 / UL Open type
4 kW (5 HP)
U1
3~380...480 V
3
I1
13.6 A
f1
48...63 Hz
U2
3~0...U1 V
I2
8.8 A (150% 1/10 min)
f2
0...500 Hz
Type designation label

Before installation

The ACS350 may be installed on the wall or in a cabinet. Check the enclosure
requirements for the need to use the NEMA 1 option in wall installations (see chapter
Technical
The drive can be mounted in three different ways, depending on the frame size:
a) back mounting (all frame sizes)
b) side mounting (frame sizes R0...R2)
c) DIN rail mounting (all frame sizes).
The drive must be installed in an upright position. Check the installation site
according to the requirements below. Refer to chapter

Requirements for the installation site

See chapter
Wall
The wall should be as close to vertical and even as possible, of non-flammable
material and strong enough to carry the weight of the drive.
Floor
The floor/material below the installation should be non-flammable.
Free space around the drive
The required free space for cooling above and below the drive is 75 mm (3 in.). No
free space is required on the sides of the drive, so they can be mounted side by side.
Mechanical installation
ACS350-03E-08A8-4
lllllllllllllllllllllllllllllllllllllll
S/N YWWRXXXX
llllllllllllllllllllllllllllllllllllllll
68468167
RoHS
data).
Technical data
1 Type code, see section
1
2 Degree of protection (IP and UL/NEMA)
3 Nominal ratings, see section
4
4 Serial number of format YWWRXXXXWS, where
Y:
5...9, A, ... for 2005...2009, 2010, ...
5
WW:
01, 02, 03, ... for week 1, week 2, week 3, ...
R:
A, B, C, ... for product revision number
6
XXXX: Integer starting every week from 0001
5 ABB MRP code of the drive
6 CE marking and C-Tick, C-UL US and RoHS marks
(the label of your drive shows the valid markings)
for the allowed operation conditions of the drive.
Type code
on page
23
Ratings
on page 290.
Dimensions
for frame details.