144
Actual signals
No.
Name/Value
0133
PID 2 DEVIATION
0134
COMM RO WORD
0135
COMM VALUE 1
0136
COMM VALUE 2
0137
PROCESS VAR 1
0138
PROCESS VAR 2
0139
PROCESS VAR 3
0140
RUN TIME
0141
MWH COUNTER
0142
REVOLUTION CNTR
0143
DRIVE ON TIME HI
0144
DRIVE ON TIME LO
0145
MOTOR TEMP
0146
MECH ANGLE
0147
MECH REVS
0148
Z PLS DETECTED
0158
PID COMM VALUE 1
0159
PID COMM VALUE 2
0160
DI 1-5 STATUS
0161
PULSE INPUT FREQ
0162
RO STATUS
0163
TO STATUS
0164
TO FREQUENCY
0165
TIMER VALUE
0166
COUNTER VALUE
0167
SEQ PROG STS
0168
SEQ PROG STATE
Actual signals and parameters
Description
Deviation of the PID2 controller, i.e. the difference between the reference
value and the actual value. Unit depends on parameter
4107
UNIT SCALE settings.
Relay output Control Word through fieldbus (decimal). See parameter
1401
RELAY OUTPUT 1.
Data received from fieldbus
Data received from fieldbus
Process variable 1 defined by parameter group
Process variable 2 defined by parameter group
Process variable 3 defined by parameter group
Elapsed time counter (thousands of hours). Runs when the drive is
running. Counter cannot be reset.
MWH counter. Counter cannot be reset.
Motor revolution counter (millions of revolutions). The counter can be
reset by pressing UP and DOWN buttons simultaneously when the
control panel is in Parameter mode.
Drive control board power-on time in days. Counter cannot be reset.
Drive control board power-on time in 2 second ticks (30 ticks = 60
seconds). Counter cannot be reset.
Measured motor temperature. Unit depends on the sensor type selected
by group
35 MOTOR TEMP MEAS
Calculated mechanical angle
Mechanical revolutions, i.e. the motor shaft revolutions calculated by the
encoder
Encoder zero pulse detector. 0 = not detected, 1 = detected.
Data received from fieldbus for PID control (PID1 and PID2)
Data received from fieldbus for PID control (PID1 and PID2)
Status of digital inputs. Example: 10000 = DI1 is on, DI2...DI5 are off.
Value of frequency input in Hz
Status of relay output. 1 = RO is energised, 0 = RO is de-energized.
Status of transistor output, when transistor output is used as a digital
output.
Transistor output frequency, when transistor output is used as a
frequency output.
Timer value of timed start/stop. See parameter group
COUNTER.
Pulse counter value of counter start/stop. See parameter group
TIMER &
COUNTER.
Status Word of the sequence programming:
Bit 0 = ENABLED (1 = enabled)
Bit 1 = STARTED
Bit 2 = PAUSED
Bit 3 = LOGIC VALUE (logic operation defined by parameters
8406...8410).
Active state of the sequence programming. 1...8 = state 1...8.
4106
34 PANEL DISPLAY
34 PANEL DISPLAY
34 PANEL DISPLAY
parameters.
19 TIMER &
FbEq
-
UNIT and
1 = 1
1 = 1
1 = 1
-
-
-
1 = 0.01 kh
1 = 1 MWh
1 = 1 Mrev
1 = 1 days
1 = 1
1 = 1
1 = 1
1 = 1
1 = 1
1 = 1
1 = 1 Hz
1 = 1
1 = 1
1 = 1 Hz
1 = 0.01 s
19
1 = 1
1 = 1
1 = 1