Reference Mode - ABB ACS350 User Manual

Hide thumbs Also See for ACS350:
Table of Contents

Advertisement

62

Reference mode

In the Reference mode, you can:
• set the speed, frequency or torque reference
• start, stop, change the direction and switch between local and remote control.
How to set the speed, frequency or torque reference
Step
Action
1.
Go to the Main menu by pressing
otherwise by pressing
2.
If the drive is in remote control (REM shown on the left), switch to local
control by pressing
to local control.
Note: With group
modification in remote control (REM).
3.
If the panel is not in the Reference mode ("rEF" not visible), press key
or
shows the current reference value with
4.
• To increase the reference value, press
• To decrease the reference value, press
The value changes immediately when you press the key. It is stored in the
drive permanent memory and restored automatically after power switch-off.
Control panels
if you are in the Output mode,
repeatedly until you see MENU at the bottom.
. The display briefly shows "LoC" before switching
LOC
REM
11 REFERENCE
SELECT, you can allow the reference
until you see "rEF" and then press
SET
. Now the display
under the value.
.
.
Display
PAr
REM
MENU
FWD
PAr
LOC
MENU
FWD
rEF
LOC
MENU
FWD
491
LOC
.
SET
FWD
500
LOC
.
SET
FWD
Hz
Hz