Setting Up the ACE
Detailed Steps
Command
Step 1
config
Example:
host1/Admin# config
host1/Admin(config)#
Step 2
clock timezone { zone_name {+ | –} hours
minutes } | {standard timezone }
Example:
host1/Admin(config)# clock timezone
PST -8 0
Cisco 4700 Series Application Control Engine Appliance Administration Guide
1-18
Purpose
Enters global configuration mode.
Configures the time zone of the ACE.
The keywords, arguments, and options are as follows:
zone_name—The 8-character name of the time zone (for
example, PDT) to be displayed when the time zone is in effect.
Table 1-1
lists the common time zone acronyms that you can use
for the zone_name argument.
hours—Hours offset from UTC. The range is from –23 to +23.
minutes—Minutes offset from UTC. The range is from 0 to 59
minutes.
standard timezone—Displays a list of well known time zones
that include an applicable UTC hours offset. Available choices in
the list are as follows:
AKST—Alaska Standard Time, as UTC –9 hours
AST—Atlantic Standard Time, as UTC –4 hours
BST—British Summer Time, as UTC + 1 hour
CEST—Central Europe Summer Time, as UTC + 2 hours
CET—Central Europe Time, as UTC + 1 hour
CST—Central Standard Time, as UTC –6 hours
CST—Central Standard Time, as UTC + 9.5 hours
EEST—Eastern Europe Summer Time, as UTC + 3 hours
EET—Eastern Europe Time, as UTC + 2 hours
EST—Eastern Standard Time, as UTC -5 hours
GMT—Greenwich Mean Time, as UTC
HST—Hawaiian Standard Time, as UTC –10 hours
IST—Irish Summer Time, as UTC + 1 hour
MSD—Moscow Summer Time, as UTC + 4 hours
MSK—Moscow Time, as UTC + 3 hours
MST—Mountain Standard Time, as UTC –7 hours
PST—Pacific Standard Time, as UTC –8 hours
WEST—Western Europe Summer Time, as UTC + 1 hour
WST—Western Standard Time, as UTC + 8 hours