Chapter 7
Configuring SNMP
Table 7-4
The clogOrigin ID and clogOriginIDType variable bindings are appended to each notification listed in
Note
Table 7-4
Table 7-4
SNMP Trap Support
Notification Name
authenticationFailure
cesRealServerStateUpRev1
cesRealServerStateDownRev1
OL-20823-01
identifies the supported SNMP notifications (traps) for the ACE.
to identify from which chassis, slot, and context combination that the event trap has originated.
Location of the
Notification
SNMPv2-MIB
CISCO-ENHANCED-
SLB-MIB
CISCO-ENHANCED-
SLB-MIB
Cisco 4700 Series Application Control Engine Appliance Administration Guide
Description
SNMP request fails because the NMS did not authenticate with
the correct community string.
State of a real server configured in a server farm is up due to
user intervention.The notification is sent with the following
varbinds:
cesRealServerName
•
cesServerFarmRserverBackupPort
•
cesServerFarmName
•
cesServerFarmRserverAdminStatus
•
cesServerFarmRserverOperStatus
•
cesRserverIpAddressType
•
cesRserverIpAddress
•
cesServerFarmRserverDescr
•
State of a real server configured in a server farm is down due to
user intervention. The notification is sent with the following
varbinds:
cesRealServerName
•
cesServerFarmRserverBackupPort
•
cesServerFarmName
•
cesServerFarmRserverAdminStatus
•
cesServerFarmRserverOperStatus
•
cesServerFarmRserverStateDescr
•
cesRserverIpAddressType
•
cesRserverIpAddress
•
cesServerFarmRserverDescr
•
Information About SNMP
7-27