Starter Solenoid Test
1. Check the hold-in coil for continuity between the S
terminal and the armature housing (ground). There
should be continuity.
• If there is continuity, go to step 2.
• If there is no continuity, replace the solenoid.
M/T:
M
2. Check the pull-in coil for continuity between the S
terminal and M terminal. There should be
continuity.
• If there is continuity, the solenoid is OK.
• If there is no continuity, replace the solenoid.