Automatic Transmission
S y s t e m Description (cont'd)
Hydraulic Flow (cont'd)
| T | Position
The PCM controls the shift solenoid valves and the A/T clutch pressure control solenoid valves. The conditions of the
shift solenoid valves and the positions of the shift valves are as f o l l o w s ;
• Shift solenoid valve A is turned OFF, and shift valve A is m o v e d t o the left side.
• Shift solenoid valve B is turned O N , and shift valve B is in the right side.
• Shift solenoid valve C is turned O N , and shift valve C is in the right side.
Line pressure (4) becomes line pressure (5B) at shift valve C. Line pressure (5C) flows to shift valve B via shift valve A,
and becomes 1st clutch pressure (10). 1st clutch pressure (10) is applied to the 1st clutch, and 1st clutch is engaged
securely.
NOTE;
• W h e n used, "left" or " r i g h t " indicates direction on the hydraulic circuit.
• Hydraulic circuit shows the '98-99 models; the '00-02 models are similar.