Changing Of Set Built-In Positioning Parameters (Number Of Pulses And Frequency - Mitsubishi Electric Melsec-F FX3GC Series User Manual

Hide thumbs Also See for Melsec-F FX3GC Series:
Table of Contents

Advertisement

FX
/FX
/FX
/FX
/FX
3S
3G
3GC
3U
3UC
Built-in Positioning Functions
11.4.2

Changing of Set Built-in Positioning Parameters (Number of Pulses and Frequency)

The "Pulse" and "Frequency" set by the built-in positioning parameters in a positioning table will be stored in
the devices starting from the specified head address as shown below. The set "Pulse" and "Frequency" can
be changed using a display module or HMI.
Caution:
If "Positioning Instruction" is set to "DPLSV [Variable speed output pulse instruction]", the "Frequency (Hz)"
value set on the screen will be stored as the set number of pulses, and the device for "Frequency" will be
"K0".
To use the "Pulse" and "Frequency" changed by a display module or HMI even after turning the
power OFF and then ON again:
Check the box.
B - 160
PLC User's Manual - Positioning Control Edition
11 Batch Data Positioning Mode - TBL Instruction
11.4 Built-in Positioning Parameter Setting
If the Head Address is set to "R0":
Pulse
output
Positioning
Pulse
destination
table No.
device
1
R1,R0
2
R5,R4
Y000
3
R9,R8
100
R397,R396
1
R401,R400
2
R405,R404
Y001
3
R409,R408
100
R797,R796
1
R801,R800
2
R805,R804
Y002
3
R809,R808
100
R1197,R1196 R1199,R1198
1
R1201,R1200 R1203,R1202
2
R1205,R1204
Y003
3
R1209,R1208
100
R1597,R1596
To use the "Pulse" and "Frequency" changed
by a display module or HMI even after turning
the power OFF and then ON again, check the
"Positioning table settings will not be initialized
when the PLC is powered on" check box in the
"Positioning Instruction Settings" screen of the
positioning parameters.
To use this function, use the uninterruptible
power supply type devices.
If this function is not set, the data set by the
built-in positioning parameters will be
initialized.
Frequency
R3,R2
R7,R6
R11,R10
R399,R398
R403,R402
R407,R406
R411,R410
R799,R798
R803,R802
R807,R806
R811,R810
R1207,R1206
R1211,R1210
R1599,R1598

Advertisement