2) To use at a position other than just below the positioning instruction:
If two or more positioning instructions are used in a program, the "Instruction execution complete" flag
(M8029) and "Instruction execution abnormal end" flag (M8329) will be turned on or off after execution of
each instruction.
If it is necessary to use the "Instruction execution complete" flag or "Instruction execution abnormal end"
flag at a point other than just below the instruction, turn on or off another bit device just below the
instruction, and use the contact as the command contact.
Switches "instruction
execution complete"
flag of the DSW
instruction from M8029
to M100.
Switches the
"instruction execution
complete" flag of the
DDRVI instruction from
M8029 to M200.
PLC User's Manual - Positioning Control Edition
M8000
FNC 72
DSW
M8029
Completion
of instruction
execution
M0
FNC158
DDRVI
M8029
Completion
of instruction
execution
Functions as the instruction
execution complete flag of
the DSW instruction.
M100
Functions as the instruction
execution complete flag of the
DDRVI instruction.
M200
4.7 Items To Be Observed in Programming
X10
Y10
D0
K10000 K10000
Y000
RST
FNC 22
D0
K10
MUL
4 Before Programming
K1
M100
Y004
M0
M200
D20
Y030
B - 83
A
B
Apx.

Advertisement

Table of Contents
loading

Table of Contents