Built-in Positioning Functions
4.3.9

Acceleration/Deceleration by PLSV Instruction

Using an FX
3UC
(M8338) is turned on, the variable speed pulse output (PLSV) instruction will be activated to accelerate/
decelerate the operation.
This means that if the command value of the output pulse frequency is changed, the operation will be
accelerated or decelerated to the changed output pulse frequency depending on the specified acceleration/
deceleration time.
Bias speed
Initial value: 0 Hz
Caution:
• To enable acceleration/deceleration, turn on M8338 first, and then activate the variable speed pulse output
(PLSV) instruction.
• If acceleration/deceleration is enabled, the variable speed pulse output (PLSV) instructions of all the pulse
output destination devices will accelerate/decelerate with the same time. This means that acceleration/
deceleration cannot be specified separately for each pulse output destination device.
B - 64
PLC User's Manual - Positioning Control Edition
PLC Ver. 2.20 or later and FX
Maximum speed
Initial value: 100,000 Hz
Output
pulse
frequency
Acceleration
time
Initial value: 100 ms
/FX
/FX
/FX
PLC, if acceleration/deceleration operation
3S
3G
3GC
3U
For operation of PLSV instruction, refer to Chapter 10.
Deceleration time
Initial value: 100 ms
4 Before Programming
4.3 Various Special Relays for Operation Commands
Bias speed