Mitsubishi Electric Melsec-F FX3GC Series User Manual page 150

Hide thumbs Also See for Melsec-F FX3GC Series:
Table of Contents

Advertisement

FX
/FX
/FX
/FX
/FX
3S
3G
3GC
3U
3UC
Built-in Positioning Functions
2. DOG search function
If the forward rotation limit and the reverse rotation limit are set, the DOG search function can be used for
zero return. The zero return operation depends on the zero return start position.
Reverse rotation
limit 1
Reverse rotation limit
1) If the start position is before the DOG:
a) When the zero return instruction is executed, zero return will be started.
b) Transfer operation will be started in the zero return direction at the zero return speed.
c) If the front end of the DOG is detected, the speed will be reduced to the creep speed.
d) After detecting the rear end of the DOG, if the first zero-phase signal is detected, the operation will be
stopped.
2) If the start position is in the DOG area:
a) When the zero return instruction is executed, zero return will be started.
b) Transfer operation will be started in the opposite direction of the zero return direction at the zero return
speed.
c) If the front end of the DOG is detected, the speed will decelerate and the operation will stop. (The
workpiece will come out of the DOG area.)
d) Transfer operation will be restarted in the zero return direction at the zero return speed (and the
workpiece will enter the DOG area again).
e) If the front end of the DOG is detected, the speed will be reduced to the creep speed.
f) After detecting the rear end of the DOG, if the first zero-phase signal is detected, the operation will be
stopped.
3) If the start position is in the near-point signal OFF area (after the DOG):
a) When the zero return instruction is executed, zero return will be started.
b) Transfer operation will be started in the zero return direction at the zero return speed.
c) If the reverse rotation limit 1 (reverse rotation limit) is detected, the speed will decelerate, and the
operation will stop.
d) Transfer operation will be started in the opposite direction of the zero return direction at the zero return
speed.
e) If the front end of the DOG is detected, the speed will be reduced and the operation will be stopped.
(The workpiece will detect the DOG and then come out of the DOG area.)
f) Transfer operation will be restarted in the zero return direction at the zero return speed. (The
workpiece will enter the DOG area again.)
g) If the front end of the DOG is detected, the speed will be reduced to the creep speed.
h) After detecting the rear end of the DOG, if the first zero-phase signal is detected, the operation will be
stopped.
B - 106
PLC User's Manual - Positioning Control Edition
4)
3)
Origin
6 Mechanical Zero Return - DSZR/ZRN Instruction
6.2 DOG Search Zero Return (DSZR Instruction)
Rear end
Front end
DOG
2)
Operation in
forward rotation
direction
Zero return
direction
Forward rotation
limit 1
Forward rotation limit
Operation in
reverse rotation
direction
1)

Advertisement

Table of Contents
loading

Table of Contents