Example Connection
*3.
To ensure safety, use the forward rotation limit switch and the reverse rotation limit switch on both sides: the PLC side and
the servo amplifier side. Note that the limit switches on the PLC side should be activated slightly earlier than the limit
switches on the servo amplifier side.
Reverse rotation limit 2
(Servo amplifier side)
Servo motor
*4.
To detect absolute positions, connect this line to the PLC.
*5.
Set the pulse output form by pulse output form setting switch.
Pulse output method setting switch
*6.
Input extension blocks are used in the connection example.
Inputs built into the main unit are available in place of extension blocks.
Appendix 2-3 Absolute Position Detection (Transistor Output)
To assign the inputs/outputs, refer to the following section.
Appendix 2-3-1 Sink Input and Sink Output
1. FX
PLC
3S
FX
-30MT/ES
3S
Photo-coupler
*1.
Be sure to use the class-D grounding method (grounding resistance: 100 or less).
Apx. - 20
PLC User's Manual - Positioning Control Edition
Reverse rotation limit 1
(Programmable
controller side)
LSR
Reverse rotation
FP
RP side
PLS
DIR side
100 to 240 V AC
L
N
Class-D
grounding
*1
S/S
0V
24V
X000
ABS (bit0)
X014
ABS (bit1)
X015
Send data ready
X016
X017
COM3
Servo-ON
Y006
ABS transfer mode
Y007
ABS request
Y010
Y011
Appendix 2-3 Absolute Position Detection (Transistor Output)
Forward rotation limit 1
(Programmable
controller side)
LSF
Forward rotation
Pulse output method
Forward/reverse pulse train
Pulse train + direction
Refer to Section 12.1 of "B. Built-in Positioning Function"
CN1
46
DOCOM
20
DICOM
24 V DC
ABSB0
22
22
ABSB0
ABSB123
ABSB1
23
ABST 25
25
ABST
15
SON
17
ABSM
18
ABSR
SD
Plate
Appendix 2. MELSERVO-J3 Series
Forward rotation limit 2
(Servo amplifier side)
MR-J3A
Series servo
amplifier