7 AUXILIARY AND APPLIED FUNCTIONS

7.7 Speed-Torque Control

QDS
This function is used to execute the speed control or torque control that does not
include the position loop for the command to servo amplifier.
The "continuous operation to torque control mode" switches the control mode to torque
control mode without stopping the servo motor during positioning operation when
tightening a bottle cap or a screw.
Switch the control mode from "position control mode" to "speed control mode", "torque
control mode" or "continuous operation to torque control mode" to execute the "Speed-
torque control".
Control mode
Position control mode
Speed control mode
Torque control mode
Continuous operation to
torque control mode
Use the servo amplifiers whose software versions are compatible with each control
mode to execute the "Speed-torque control".
Servo amplifier software versions that are compatible with each control mode are
shown below.
Servo amplifier model
MR-J4- B
MR-J4W- B
MR-J3- B
MR-J3W- B
MR-J3- B Safety
(Note-1): In the servo amplifier that supports continuous operation to torque control, the torque generation
direction of servo motor can be switched by setting "Function selection C-B (PC29) (POL reflection
selection at torque control)". (Refer to Section 7.7.1 (7).)
In the servo amplifier that does not support continuous operation to torque control, the operation is
the same as when "0: Valid" is set in "Function selection C-B (PC29) (POL reflection selection at
torque control)".
Control
(Note-1)
Positioning control
home position return control,
JOG operation, and manual
pulse generator operation
Speed-torque control
Speed control
Torque control
7 - 14
Remark
,
Control that include the position loop
for the command to servo amplifier
Control that does not include the
position loop for the command to
servo amplifier
Control that does not include the
position loop for the command to
servo amplifier
Control mode can be switched during
positioning control or speed control.
(Note-1): Excluding speed control ( ).
Software version
Continuous operation
(Note-1)
B3 or later
—: There is no restriction by the version.
to torque control
C7 or later
Not compatible
C7 or later