Mitsubishi Electric MELSEC Q Series Programming Manual page 523

Motion controller, real mode
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

APPENDICES
Control mode
Error
code
1310
1350
1360
1361
1362
1363
1365
(4) System errors (1300 to 1399)
These errors are detected at the power-on.
The error codes, causes, processing and corrective actions are shown in Table
1.11.
Table 1.11 System error (1300 to 1399) list
Error cause
• Initial communication with
the Multiple CPU system did
not complete normally.
• Motion CPU fault.
• An operation cycle that the
servo amplifier does not
support has been set.
• Number of axes set for the
master axis in servo
parameter "Driver
communication setting
(PD15)" exceed the setting
range.
• Servo parameters "Driver
communication setting
Master axis No. selection 1
for slave (PD20)" or "PD21
to PD23" are set the self
axis.
• There is no master axis
setting corresponding to the
slave axis.
• Setting the driver
communication to servo
amplifier which does not
support the driver
communication.
• Setting the driver
communication in the
operation cycle setting of
0.2ms.
APP - 32
Error
Corrective action
processing
• Replace the Motion CPU.
Positioning
control does
not start.
• Set an operation cycle that is
supported.
• Set the number of master axis
to 4 axes or less for SSCNET
lines, and 8 axes or less for
SSCNET /H lines in servo
parameter "PD15".
• Review the servo parameters
"PD20" or "PD21 to PD23" of
applicable slave axis.
System
setting error
• Confirm the driver
communication and the
actually connected servo
amplifier.
• For SSCNET , set the
operation cycle setting to
0.4ms or more.

Hide quick links: