6 POSITIONING CONTROL

6.21.3 Simultaneous start

[Control details]
Simultaneous start JOG operation for specified multiple axes.
(1) JOG operation continues at the JOG speed setting register value for each axis
while the JOG operation simultaneous start command (M2048) turns on, and a
deceleration stop is made by the M2048 OFF.
Control of acceleration/deceleration is based on the data set in the JOG operation
data.
JOG operation simultaneous
start axis setting register
(D710 to D713)
JOG operation simultaneous
start command (M2048)
(2) JOG operation axis is set in the JOG operation simultaneous start axis setting
register (D710 to D713).
b15 b14 b13 b12 b11 b10
D710
Axis 16 Axis 15 Axis 14 Axis 13 Axis 12 Axis 11 Axis 10 Axis 9
D711
Axis 32 Axis 31 Axis 30 Axis 29 Axis 28 Axis 27 Axis 26 Axis 25 Axis 24 Axis 23 Axis 22 Axis 21 Axis 20 Axis 19 Axis 18 Axis 17
D712
Axis 16 Axis 15 Axis 14 Axis 13 Axis 12 Axis 11 Axis 10 Axis 9
D713
Axis 32 Axis 31 Axis 30 Axis 29 Axis 28 Axis 27 Axis 26 Axis 25 Axis 24 Axis 23 Axis 22 Axis 21 Axis 20 Axis 19 Axis 18 Axis 17
Acceleration based on
V
JOG operation data
JOG operation based
on D710 to D713 data
ON
OFF
b9
b8
b7
Axis 8 Axis 7 Axis 6 Axis 5 Axis 4 Axis 3 Axis 2 Axis 1
Axis 8 Axis 7 Axis 6 Axis 5 Axis 4 Axis 3 Axis 2 Axis 1
(Note-1): Make JOG operation simultaneous start axis setting with 1/0.
1: Simultaneous start execution
0: Simultaneous start not execution
(Note-2): The following range is valid.
Q172DSCPU
: Axis No.1 to 16
Q172DCPU(-S1) : Axis No.1 to 8
6 - 189
JOG operation speed
Deceleration stop based
on JOG operation data
b6
b5
b4
b3
b2
b1
t
b0
Forward
rotation
JOG
Reverse
rotation
JOG