Mitsubishi Electric MELSEC Q Series Programming Manual page 136

Motion controller, real mode
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

4 PARAMETERS FOR POSITIONING CONTROL
No.
Item
mm
Setting range Units Setting range Units Setting range
Torque limit
8
value
Deceleration
0 : Deceleration stop is executed based on the deceleration time.
9
processing on
1 : Deceleration stop is executed based on the rapid stop deceleration time.
STOP input
Allowable error
10
range for circular
0 to 10000.0
interpolation
(Note-1): When the "speed control 10 multiplier setting for degree axis" is set to "valid", the setting range is 0.01 to 21474836.47[degree/min].
However, setting range of 0.001 to 2147483.647[degree/min] is displayed in the parameter block setting screen of MT Developer2.
Table 4.2 Parameter Block Setting List (Continued)
Setting range
inch
1 to 1000[%]
µm
0 to 1.00000 inch 0 to 1.00000 degree 0 to 100000
POINTS
(1) Parameter blocks are specified in the home position return data, JOG operation
data or servo program.
(2) The various parameter block data can be changed using the servo program.
(Refer to Section 5.3.)
(3) The data set in the parameter block is used in the positioning control, home
position return and JOG operation.
(a) The parameter block No. used in the positioning control is set using MT
Developer2 at the creating of the servo program. If it is not set, control is
executed with the contents of parameter block No.1.
Also, it is possible to set parameter block data individually in the servo
program.
[Servo program editor screen]
Unit
: Interpolation control unit
: Acceleration time
E
: Rapid stop deceleration time
STOP : Deceleration processing on STOP input
S Ratio : S-curve ratio when S-pattern processing
is executed
pulse
degree
Units
Setting range Units
pulse
S.R.
P. Torque
Adv. S-curve : Advanced S-curve acceleration/
4 - 15
Initial
Units
Remarks
value
• Set the torque limit value in
300
%
the servo program.
• Set the deceleration
processing when external
0
signals (STOP, FLS, RLS)
are input.
• Set the permissible range for
pulse
100
the locus of the arc and the
set end point coordinates.
Parameter block No.
setting
Setting items of the
parameter block
Individual parameter
block data setting
: Speed limit value
: Deceleration time
: Torque limit value
: Allowable error range for circular
interpolation
deceleration
Section
4.3.4