3.8.6 Resetting the program

The program's stopped state is canceled, and the execution line is returned to the head.

(1) Operating with the controller

Prepare the control
T/B disable
Controller enable
CHNG DISP
Display the program No.
Execute of program reset
Reset
RESET

(2) Operating with the T/B

Controller disable
T/B enable
Execute of program reset
Program reset [RESET] + [EXE]
Valid only while program is stopped
The program cannot be reset while the program is running. Always carry out this step while the program is
stopped.
When resetting the program from the controller operation panel, display the "program No." on the STA-
TUS NUMBER display, and then reset.
STOP lamp turns OFF
The STOP lamp will turn OFF when the program is reset.
Up :DISABLE
Down:ENABLE
*Lighting
Rear of T/B
MODE
MANUAL
AUTOMATIC
MODE
MANUAL
AUTOMATIC
Up :DISABLE
Down:ENABLE
*Lighting
Rear of T/B
3Explanation of operation methods
1) Set the T/B [ENABLE] switch to "DISABLE".
2) Set the controller mode to "AUTOMATIC".
3) Press the controller [CHG DISP] switch, and
display the program No.
4) Press the controller [RESET] switch.
The STOP lamp will turn OFF, and the pro-
gram's stopped state will be canceled.
1) Set the controller mode to "MANUAL".
2) Set the T/B [ENABLE] switch to "ENABLE".
3) Press the [EXE] key while holding down the
[RESET] key. The execution line will return to
the head, and the program will be reset.