Example Of Setting Of Parameter 1 (When The Support Software Is Used) - Mitsubishi Electric CR750-Q Instruction Manual

Cr750/cr751/cr760 series
Hide thumbs Also See for CR750-Q:
Table of Contents

Advertisement

5.15.2 Example of setting of parameter 1 (When the Support Software is used)

The setting example to use the Support Software is shown below.
Set the parameters for the robot controller, and the network for the personal computer OS being used.
Item
IP address of robot controller
IP address of personal computer
Port No. of robot controller 10001
Set the robot controller parameters as shown below.
If the default settings are to be used, the parameters do not need to be changed.
Parameter name to be changed
NETIP
NETPORT
Next, set the personal computer IP address to 192.168.0.2. Set this value on the Network Properties
screen.
Windows XP (lower left screen), Windows Vista (lower right screen)
The personal computer IP address is set with the Windows TCP/IP Property Network setting (property in
network computer). Because the set-up screen differs with versions of Windows, refer to the manuals
enclosed with Windows, etc., for details on setting this address.
Refer to the instruction manuals enclosed with the personal computer support software for details on setting
and using the personal computer support software.
Setting value
192.168.0.20
192.168.0.2
10001
Before/after change
Before
192.168.0.20
After
192.168.0.20 (With the default value.)
Before
10001
After
10001 (With the default value.)
5Functions set with parameters
Parameter value
About the communication setting (Ethernet) 5-491