Mitsubishi Electric CR750-Q Instruction Manual page 560

Cr750/cr751/cr760 series
Hide thumbs Also See for CR750-Q:
Table of Contents

Advertisement

5Functions set with parameters
(1) Setting the calibration
Set the
Base coordinate system
robots, in parameter: RBCORD with the X, Y, Z, A, B and C coordinate values.
Note) When using a locomotion axis, set the positional relation for when the locomotion axis coordinate
value is "0".
Table 5-40:Set parameters for calibration between robots
Parameter
Common coordi-
RBCORD
nates for robots
(2) Checking the calibration setting results
Check that each robot has been correctly calibrated with the following steps.
1) Looking at the system layout drawing, etc., set one reference point for each robot.
inafter, reference point)
2) Move the tip of the robot hand to the set reference point using jog operations.
3) Check the robot (system) status variable:
dinates) using T/B, etc.
4) Compare the above
Only the XYZ values are compared. If the values match, the robot has been correctly calibrated. If the
values do not match, correct the parameter:
5) Carry out the above steps for all robots which are using the interference avoidance function.
Fig.5-26:Checking the setting for calibration between robots
6-540 Interference avoidance function
origin point for each robot, looking from the common coordinates between
Parameter
No. of arrays
name
No. of characters
Real number 6
P_CurrR
value to the value on the layout drawing, etc.
Details explanation
The robot's
Base coordinate system
from the common coordinates between robots.
(Designate with X, Y, Z, A, B and C coordinate values)
1st element: X-axis coordinate value (mm)
2nd element: Y-axis coordinate value (mm)
3rd element: Z-axis coordinate value (mm)
4th element: A-axis coordinate value (deg)
(Rotation angle around X axis)
5th element: B-axis coordinate value (deg) (Rotation
angle around Y axis)
6th element: C-axis coordinate value (deg) (Rotation
angle around Z axis)
Note 1) For the A, B and C-axis coordinate values
(rotation angles), set the values obtained by
rotating in the order of around Z axis → around
Y axis → around X axis.
P_CurrR
(current robot position looking from common coor-
RBCORD
setting value.
Check details
Compare the robot (system) status variable:
and the value from the layout diagram, etc. The set-
ting is correct if the values match.
Set to the reference point
a) Reference point
Refer to layout drawing,
etc., and determine.
Factory setting
origin point looking
0.00, 0.00, 0.00,
0.00, 0.00, 0.00,
(Fig. 5-26
P_CurrR
a) (Here-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cr750Cr751-qCr751-dCr760-dCr760-qCr750-d

Table of Contents