MODEL 7561-PSDS
PORTABLE SENSOR DISPLAY – STRAIN BRIDGE
| |-ALARM ACTION u
|
|-—NONE
|
|
|
|-—BEEP
|
|-—FLASH
|
|-—BOTH
|
|-MEASUREMENT u
| |-MEASUREMENT RATE
| | |
| | |
| | |-—1 SPS
| | |-—3 SPS
| | |-—10 SPS
| | |-—50 SPS
| | |-—100 SPS
| | |-—1200 SPS
| | |-—2400 SPS
| |-MEASUREMENT QUALITY u
| | |
| | |-—LOW
| | |-—HIGH
| |-CURRENT RANGE u
|
|-SYSTEM ZERO u
|
| |-VIEW/EDIT ZERO ———
|
| |-ZERO NOW
|
| |-REMOVE ZERO
|
|-TARE VALUE u
|
| |-VIEW/EDIT TARE ———
|
| |-TARE NOW
|
| |-REMOVE TARE
|
|-SCALE STEADY u
|
| |-BAND ———
|
| |-INTERVAL ———
|
|
|
|-SET ZERO MASK ———
|
|
|
|
|
|-SET RESOLUTION ———
|
|
|
|-SET MIN LIMIT ———
|
|
|
|
|
|-SET MAX LIMIT ———
|
|
Select one of these actions to occur when the Alarm is triggered
No action. (will still trigger warning icon and Pass/Fail Display
Mode will still operate)
Play beep sound
Flash the main display
Do both
Allows configuration of the various measurement settings
Select the required Measurement Rate at which new values will
be generated. The faster the rate the more this affects battery life.
(SPS = Samples Per Second)
One per second
Three per second
Ten per second
Fifty per second
One hundred per second
One thousand two hundred per second
Two thousand four hundred per second
Select the desired quality. This will affect the noise free resolution
and battery life
Lowest quality
High quality
Configure the System Zero options
Configure the System Zero options
Display and edit the current Zero value
Perform a System Zero now
Remove any existing System Zero value
Configure the Tare options
Display and edit the current Tare value
Perform a Tare now
Remove any existing Tare value
Configure the Scale Steady values
Display and edit the Scale Steady ± band
Display and edit the time interval over which the value must be
within the band to constitute Scale Steady
Display and edit the Zero Mask value. This is entered in base
calibrated units for this range and when the value is less than this
level a zero will be displayed
Display and edit the Resolution value in base calibrated units for
this range. The display will change in increments of this value
Display and edit the Minimum user level in base units for this
range. When the value falls below this a full screen Underrange
message will be displayed
Display and edit the Maximum user level in base units for this
range. When the value falls below this a full screen Overrange
message will be displayed