Honeywell 7561-PSDS User Manual
Honeywell 7561-PSDS User Manual

Honeywell 7561-PSDS User Manual

Portable sensor display
Table of Contents

Advertisement

Quick Links

MODEL
Issue A
008-0752-00
7561-PSDS
PORTABLE
SENSOR DISPLAY
User Manual
Model 7561-PSDS

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell 7561-PSDS

  • Page 1 MODEL Issue A 008-0752-00 7561-PSDS PORTABLE SENSOR DISPLAY User Manual Model 7561-PSDS...
  • Page 2 DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. Model 7561-PSDS User Manual | sps.honeywell.com/ast...
  • Page 3: Table Of Contents

    Where There is No Option to Connect to Strain Bridge Sensor Chassis ..........33 Model 7561-PSDS User Manual |...
  • Page 4 Electrical, Mechanical & Environmental ..................72 Units of Measure Model 7561-PSDS User Manual | sps.honeywell.com/ast...
  • Page 5: Introduction/Overview

    • Display hold/freeze • Gross/Net indication selection • Peak hold selection • Trough hold selection • TEDS support The PSD is powered by two internal non-rechargeable AA alkaline batteries and can also be USB powered. Model 7561-PSDS User Manual | sps.honeywell.com/ast...
  • Page 6: Key Concepts

    There are up to six available display modes that can be cycled through and can be selected from a library of different scenarios when using the Toolkit to configure the handheld. These display modes are independent to whatever Calibration Range is currently selected. Model 7561-PSDS User Manual | sps.honeywell.com/ast...
  • Page 7: Decimal Point Position And Resolution

    TEDS works in a similar way in which USB computer peripherals immediately work as they are connected. TEDS enabled equipment may be swapped and changed without recalibration, saving time and money. Model 7561-PSDS User Manual | sps.honeywell.com/ast...
  • Page 8: How It Works

    ID=41 (polynomial calibration). When you first connect a new TEDS device to the PSD a message will be displayed stating that a new TEDS device has been detected and that default settings have been used. Model 7561-PSDS User Manual | sps.honeywell.com/ast...
  • Page 9: Supported Teds Hardware Devices

    For practical reasons the PSD imposes restrictions on the size and complexity that is allowed. Multi-Point Calibration (template ID=40) • Maximum calibration points = 10 Polynomial Calibration (template ID=41) • Maximum number of segments = 1 • Maximum number of coefficients = 10 (10th order polynomial) Model 7561-PSDS User Manual | sps.honeywell.com/ast...
  • Page 10: Displayed Error Codes

    TEDS contains too many calibration templates (>5) Template 40 contains too many calibration points (>10) Template 41 contains too many polynomial coefficients (>10) Template 41 contains too many segments (>1) Template 42 contains too many entries (>10) Model 7561-PSDS User Manual | sps.honeywell.com/ast | 10...
  • Page 11: Configuration Customization

    A forgotten password cannot be recovered but the protected sections can be unprotected again. This will involve contacting your supplier as Honeywell will need to verify that you have the rights to the protected data. There will be a charge for this service.
  • Page 12: Measurement Block

    The following diagram shows how values and flags are generated. This entire block is processed at the Measurement Rate selected. Some processes (such as the calibration and linearization) are only shown as a single block due to their complexity. Figure 3. Measurement Block Model 7561-PSDS User Manual | sps.honeywell.com/ast | 12...
  • Page 13: User Operation

    In both the menu and the toolkit, the user may also select an action for a long press. A long press is when the key is held down for over a second before being released. Model 7561-PSDS User Manual | sps.honeywell.com/ast | 13...
  • Page 14: Display

    The values for the main, secondary, and tertiary items are not indicated on the above diagram to improve clarity. Other modes such as the menu or editing values will be shown in the appropriate sections of the manual. Model 7561-PSDS User Manual | sps.honeywell.com/ast | 14...
  • Page 15: Default Display Modes

    The Gross value and the value of Tare are continuously displayed under the main value. Soft keys allow the user to Zero the main display, switch back to full Gross value, or change displayed units. Model 7561-PSDS User Manual | sps.honeywell.com/ast | 15...
  • Page 16: Hold

    Figure 10. Display - Delta Soft keys allow the user to Reset the min. and max. to the current value, i.e. zero the Delta. The usual Units selection is also available. Model 7561-PSDS User Manual | sps.honeywell.com/ast | 16...
  • Page 17: Go/No Go

    As there is only one global alarm, set in the base units of the current selected calibration range, the user must ensure that the correct calibration range is selected and that the Alarm Latch is not active! Model 7561-PSDS User Manual | sps.honeywell.com/ast | 17...
  • Page 18: Icons

    The Scale Steady functionality is active, but the reading is not steady A TEDs device is detected as being connected. The TEDs device is using an internal calibration range rather that its own calibration table Model 7561-PSDS User Manual | sps.honeywell.com/ast | 18...
  • Page 19: Full Screen Messages

    Note: Because the keypad gets locked during toolkit configuration, avoid swapping TEDS devices while connected to the toolkit any full screen messages that may appear will not be able to be dismissed. Model 7561-PSDS User Manual | sps.honeywell.com/ast | 19...
  • Page 20: Menu

    Some items will lead to a displayed value or text that may be edited. See the next section regarding Editing Values where this is described. Shown as a following ——— for clarity Model 7561-PSDS User Manual | sps.honeywell.com/ast | 20...
  • Page 21: Menu Structure

    Select this item to choose the action when the up and down keys | | | | are pressed and released after around one second (when not in the | | | | menu) Model 7561-PSDS User Manual | sps.honeywell.com/ast | 21...
  • Page 22 Alarm is triggered when the source value is above the Alarm Low | | | level | | |-—BELOW LOW Alarm is triggered when the source value is below the Alarm Low level Model 7561-PSDS User Manual | sps.honeywell.com/ast | 22...
  • Page 23 |-SET MAX LIMIT ——— Display and edit the Maximum user level in base units for this range. When the value falls below this a full screen Overrange message will be displayed Model 7561-PSDS User Manual | sps.honeywell.com/ast | 23...
  • Page 24 | | |-CAPTURE mV/V HIGH ready to either select OK or to manually edit | | | | |-APPLY——— Use all of the information captured above to perform the actual calibration Model 7561-PSDS User Manual | sps.honeywell.com/ast | 24...
  • Page 25 This will also allow unit conversion to selectable, using up to three of the remaining custom units slots |-—TEDS UNITS Use the units specified in the TEDS device |-—CUSTOM UNITS Use the first custom units item instead of the TEDS units Model 7561-PSDS User Manual | sps.honeywell.com/ast | 25...
  • Page 26: Editing Parameter Values

    Move the decimal place to the right Click the OK key to stop editing and save the value NOTE Pressing and holding the OK key for over a second then releasing will cancel the current edit. Model 7561-PSDS User Manual | sps.honeywell.com/ast | 26...
  • Page 27: Editing Text

    Cycle between character modes. Alpha, numeric and symbol Click the OK key to stop editing and save the value NOTE Pressing and holding the OK key for over a second then releasing will cancel the current edit. Model 7561-PSDS User Manual | sps.honeywell.com/ast | 27...
  • Page 28: Connections

    Cable screen should only be connected Shield/ to chassis of the sensor. If this cannot Grey Screen be achieved, it should be connected to Excitation –ve View from solder connector side of the connector Model 7561-PSDS User Manual | sps.honeywell.com/ast | 28...
  • Page 29: Field Cable Preparation (4 Wire Shown)

    If the main body is difficult to unscrew, it may be easier to lock the connector to the handheld. Grip and unscrew the main body in a counter-clockwise direction. Model 7561-PSDS User Manual | sps.honeywell.com/ast | 29...
  • Page 30: Four (4) Wire & Six (6) Wire Measurement Explained

    Note: shield connections are described further on in this section. Also, the extra two cores required for TEDs connection (If used) are not shown in the diagram. Figure 18. Wiring a Six Wire Strain Bridge Sensor Model 7561-PSDS User Manual | sps.honeywell.com/ast | 30...
  • Page 31: Wiring A Four Wire Strain Bridge Sensor (Existing Four Wire Cable)

    Also, the extra two cores required for TEDs connection (If used) are not shown in the diagram. Figure 20. Wiring a Four-Wire Strain Bridge Sensor (On extended six-wire cable) Model 7561-PSDS User Manual | sps.honeywell.com/ast | 31...
  • Page 32: Wiring A Four Wire Strain Bridge Sensor When Four Wire Measurement Configured

    Where Strain Bridge Sensor Chassis is Metallic (or surrounding strain bridge sensor structure) Cable shield should be connected to the strain bridge sensor chassis and remain unconnected at the PSDS end. Figure 22. Strain Bridge Sensor Chassis is Metallic Model 7561-PSDS User Manual | sps.honeywell.com/ast | 32...
  • Page 33: Where There Is No Option To Connect To Strain Bridge Sensor Chassis

    Where There is No Option to Connect to Strain Bridge Sensor Chassis Cable shield should be connected to the PSDS Excitation -ve and remain unconnected at the strain bridge sensor end. Figure 23. No Option to Connect to Strain Bridge Sensor Chassis Model 7561-PSDS User Manual | sps.honeywell.com/ast | 33...
  • Page 34: Toolkit Configuration

    Description Select from the list of detected serial ports. Select the Serial Port drop-down one that the handheld is connected to Connect button Connect to the device using the selected serial port Model 7561-PSDS User Manual | sps.honeywell.com/ast | 34...
  • Page 35: Information

    MODEL 7561-PSDS Issue A PORTABLE SENSOR DISPLAY – STRAIN BRIDGE 008-0752-00 Information Figure 25. Information Screen This page displays useful information about the connected handheld. Model 7561-PSDS User Manual | sps.honeywell.com/ast | 35...
  • Page 36: Settings

    Enabled switch are not pressed for a specified duration Duration (minutes) entry Set the time to wait without a key press before the backlight turns off. Only applies if Auto-Off is enabled field Model 7561-PSDS User Manual | sps.honeywell.com/ast | 36...
  • Page 37: Key Actions Tab

    Short Press drop-down Decimal Places - Increase or decrease the number list of decimal places displayed for all displayed values using the same units as the main display Disabled - No action Model 7561-PSDS User Manual | sps.honeywell.com/ast | 37...
  • Page 38 Long Press drop-down list Decimal Places - Increase or decrease the number of decimal places displayed for all displayed values using the same units as the main display Disabled - No action Model 7561-PSDS User Manual | sps.honeywell.com/ast | 38...
  • Page 39: Clock Tab

    Set the handheld internal clock month Day entry field Set the handheld internal clock day Date format drop down Select the desired date format list Use Computer Time Set handheld to PC time and date button Model 7561-PSDS User Manual | sps.honeywell.com/ast | 39...
  • Page 40: Import/Export

    Export configuration to a file on the PC. This will open Export button a file dialog box to allow the user to specify where the export will be saved Clone Export button See the next section in the manual Model 7561-PSDS User Manual | sps.honeywell.com/ast | 40...
  • Page 41: Export Tab - Clone Export

    Go back to standard export page Export Clone configuration to a file on the PC. This will Clone Export button open a file dialog box to allow the user to specify where the export will be saved Model 7561-PSDS User Manual | sps.honeywell.com/ast | 41...
  • Page 42: Import Tab

    Calibration – Calibration settings Configuration – The configuration includes what settings are available to change, which menu items are visible, etc. This also includes the Display Modes. Settings – All general settings Model 7561-PSDS User Manual | sps.honeywell.com/ast | 42...
  • Page 43: Clone Export File

    TABLE 16. CLONED EXPORT FILE Item Description Click to open a file select dialog box to allow the user to Select File button choose the location of the file to import Import button Perform the import Model 7561-PSDS User Manual | sps.honeywell.com/ast | 43...
  • Page 44: Configuration

    Refer to the Menu Structure section to see what functionality the above menu options contain. Note that individual menu items (those not shown above) are not available for individually hiding. Off – Menu item will be hidden On – Menu item will be visible Model 7561-PSDS User Manual | sps.honeywell.com/ast | 44...
  • Page 45: Calibration Tab

    On – This calibration range can be calibrated by the user The calibration availability is useful for providing preset calibration ranges that cannot be recalibrated, whilst still allowing other ranges to be calibrated by the user. Model 7561-PSDS User Manual | sps.honeywell.com/ast | 45...
  • Page 46: Display Modes Tab

    The selection options here will not stop that action, but only the selection from the keypad. Off – Display Mode is unavailable for selection On – Display Mode is available for selection Model 7561-PSDS User Manual | sps.honeywell.com/ast | 46...
  • Page 47: Units Tab

    Note: the decimal places can also be modified (globally for the currently displayed engineering units) by using a long press on the keypad left and right direction keys (If this action has been allowed). Model 7561-PSDS User Manual | sps.honeywell.com/ast | 47...
  • Page 48: Custom Units Tab

    For example, if trying to enter mass units and wanted kg and lbs, the user could enter kg in index 1 with a gain of 1 and lbs in index 2 with a gain of 2.2 Model 7561-PSDS User Manual | sps.honeywell.com/ast | 48...
  • Page 49: Firmware Upgrade Tab

    Firmware Upgrade button Click Load File button to select the .srec firmware file. Click Start Programming to initiate the update, then follow onscreen instructions. (Remove all power from the device before attempting to reconnect.) Model 7561-PSDS User Manual | sps.honeywell.com/ast | 49...
  • Page 50: Displays Tab

    The currently selected Display Mode of the handheld is indicated by the display number being shown in triangular brackets. The right-most column shows a graphical mimic of how the display is formatted. Figure 38. Summary Sub Tab Screen Model 7561-PSDS User Manual | sps.honeywell.com/ast | 50...
  • Page 51: Mode 1

    Swap the current display mode with the one in another Swap With buttons slot Select a new display mode for the current slot. See the Select New button next section for a description of this process Model 7561-PSDS User Manual | sps.honeywell.com/ast | 51...
  • Page 52: Select New

    Opens the file dialog window to allow a Display Mode Import button Descriptor file to be located and imported. Display Mode Descriptor files have an .ies file extension Model 7561-PSDS User Manual | sps.honeywell.com/ast | 52...
  • Page 53: Management Tab

    Measurements inputs when using 4-wire inputs on a 6-wire measurement switch system. Note: when using 4-wire measurement, the cable lengths will not be compensated for Model 7561-PSDS User Manual | sps.honeywell.com/ast | 53...
  • Page 54: Logging

    Double-click to select the folder and filename for the Log File entry field logged file Start logging. The user will be warned if the file already Start Logging button exists and given the option to continue or cancel the operation Model 7561-PSDS User Manual | sps.honeywell.com/ast | 54...
  • Page 55 Off - Nothing is displayed Show Value switch On - Display pop-up information box showing the time and value of the data point under the mouse pointer Model 7561-PSDS User Manual | sps.honeywell.com/ast | 55...
  • Page 56 This is what the caption of the Load Log File button Back to Real-time Chart changes to while a logged file is opened in the chart. button Clicking the button will revert the chart to showing real-time data Model 7561-PSDS User Manual | sps.honeywell.com/ast | 56...
  • Page 57: Measurement

    Live Values are referring to and will also set what the System Zero, Zero Masking, Resolution and Scale Steady settings refer to i.e., these settings are independent for each internal Calibration Range Model 7561-PSDS User Manual | sps.honeywell.com/ast | 57...
  • Page 58 This value can be directly edited or the following two buttons used to change the value Set the value of System Zero to the current calibrated Zero Now button engineering to give a zero Gross value Model 7561-PSDS User Manual | sps.honeywell.com/ast | 58...
  • Page 59 Simulated display value showing the effects of the Zero Display Value live label Masking and Resolution settings NOTE If a TEDS device is connected, this page will reflect the settings particular to that device. Model 7561-PSDS User Manual | sps.honeywell.com/ast | 59...
  • Page 60: Calibration

    ±15 mV/V ±30 mV/V Sensitivity header ±60 mV/V ±120 mV/V ±240 mV/V ±480 mV/V Date header The date when the calibration was performed Initials header The initials entered at the time of calibration Model 7561-PSDS User Manual | sps.honeywell.com/ast | 60...
  • Page 61: Range 1 - 6 Tabs

    Select the engineering units that this calibration range will be calibrated in. Depending on the chosen units Units drop down here, this will limit the available conversion units to those compatible with the selected units Model 7561-PSDS User Manual | sps.honeywell.com/ast | 61...
  • Page 62 Allows the last performed step to be undone Import button Import a previously exported calibration data file Export the current calibration to a file for later import Export button into the same or a different handheld Model 7561-PSDS User Manual | sps.honeywell.com/ast | 62...
  • Page 63: Calibration Types

    NO header refers to. In this case there is only ever one point Offset edit field Click and enter the required offset value Gain edit field Click and enter the required gain value Model 7561-PSDS User Manual | sps.honeywell.com/ast | 63...
  • Page 64: Multi-Point

    10 kg and enter 10 in the Output field then click Acquire to automatically enter the current input value Click and enter the required output value for the given Output edit field input value Model 7561-PSDS User Manual | sps.honeywell.com/ast | 64...
  • Page 65: Polynomial

    TABLE 28. POLYNOMIAL SCREEN Item Description This simply indicates which calibration point the row No header refers to. Value edit field Enter the polynomial value for this point Model 7561-PSDS User Manual | sps.honeywell.com/ast | 65...
  • Page 66: Management Tab

    Clear Password button to remove protection of the configuration settings NOTE A forgotten password cannot be recovered, and the handheld may need to be returned to the supplier. DO NOT FORGET YOUR PASSWORD! Model 7561-PSDS User Manual | sps.honeywell.com/ast | 66...
  • Page 67: Alarm

    This is Unlatched operation. Latched operation means that Latched switch the alarm stays active even when the source value is within limits again and requires a manual reset (via menu) to deactivate Model 7561-PSDS User Manual | sps.honeywell.com/ast | 67...
  • Page 68 Alarm Properties image alarm will not activate. This action is changed by selecting a different Trigger above This indicates which of the eight alarm flags are cur- Alarm Flags indicator rently active Model 7561-PSDS User Manual | sps.honeywell.com/ast | 68...
  • Page 69: Enclosure

    Before re-attaching the battery compartment cover, check the rubber seals and grooves for any debris that may compromise the enclosure’s water resistance. NOTE The battery compartment cover should remain with the handheld case it was shipped with. Model 7561-PSDS User Manual | sps.honeywell.com/ast | 69...
  • Page 70: Usb Connection

    Although any micro USB cable can be plugged into the PSDS for communications and configuration a right-angled connector puts less mechanical strain on the connector and socket. The correctly orientated right angle USB cables are available as an accessory. Figure 53. Part Number: 023-1718-00 Model 7561-PSDS User Manual | sps.honeywell.com/ast | 70...
  • Page 71: Connector Conversion Cable

    Connector Conversion Cable This cable allows the original PSD connector to be plugged in to the new PSDS using a conversion cable. The cable length is 300 mm. Figure 54. Part Number: 023-1719-00 Model 7561-PSDS User Manual | sps.honeywell.com/ast | 71...
  • Page 72: Specification

    Storage temperature range °C Operating humidity range Environmental protection IP64 (with connector mated or unmated) External dimensions 170 mm L × 94 mm W × 42 mm H excluding mated connector Weight including batteries Model 7561-PSDS User Manual | sps.honeywell.com/ast | 72...
  • Page 73: Units Of Measure

    Å astronomical unit centimeters chains gunters fathoms feet furlongs inches kilometers Length league leagues league light years lines microns miles nautical mi n miles millimeters mils nanometers parsec yard Model 7561-PSDS User Manual | sps.honeywell.com/ast | 73...
  • Page 74 J/cm Force kilograms force kilograms force kp kilograms meter/second² Kg ms² ounces force pounds force poundals tons force long tonfl tons force short tonfs tons force metric tonfm kilo pounds force klbf Model 7561-PSDS User Manual | sps.honeywell.com/ast | 74...
  • Page 75 Speed meters/hr meters/min m/min miles/hr miles/min miles/sec nautical miles/hr n mph nautical miles/min n mpm nautical miles/sec n mps radians/sec rad/s Angular Velocity degrees/sec °/s Torrosional Stiffness newton meter per radian Nm/rad Model 7561-PSDS User Manual | sps.honeywell.com/ast | 75...
  • Page 76 RMS Power mW rms microwatts rms kilowatts rms kW rms watts milliwatts Power microwatts kilowatts horsepower celcius °C Temperature fahrenheit °F kelvin Counts counts counts ε strain Strain mε microstrain Model 7561-PSDS User Manual | sps.honeywell.com/ast | 76...
  • Page 77 Acceleration g-force foot per second² ft/sec² custom unit 1 custom1 custom unit 2 custom2 Custom custom unit 3 custom3 custom unit 4 custom4 undefined Model 7561-PSDS User Manual | sps.honeywell.com/ast | 77...
  • Page 78 Safety Technologies Windows is a trademark or registered trademark of Micro- soft Corporation in the United States and other countries. 830 East Arapaho Road Richardson, TX 75081 008-0752-00-EN | A | 12/23 www.honeywell.com © 2023 Honeywell International Inc. All rights reserved.

Table of Contents