MODEL 7561-PSDS
PORTABLE SENSOR DISPLAY – STRAIN BRIDGE
| | | |-—RANGE SELECTION
| | | |
| | | |-—DISPLAY SELECTION
| | | |-—DECIMAL PLACES
| | | |
| | | |-—DISABLED
| | |-LONG LEFT/RIGHT u
| | | |
| | | |
| | | |-—NONE
| | | |-—RANGE SELECTION
| | | |
| | | |-—DISPLAY SELECTION
| | | |-—DECIMAL PLACES
| |
| |
| |
| |-TIME & DATE u
| | |-TIME NOW ———
| | |-SET DATE ———
| | |-SET TIME ———
| | |-DATE FORMAT u
| |
|-—YYYY/MM/DD FORMAT
| |
|-—DD/MM/YYYY FORMAT
| |
|-—YMM/DD/YYYY FORMAT
| |
| |-ABOUT u
|
|-ALARM u
| |-**ALARM CANCEL**
| |
| |-ALARM SOURCE u
| | |-—GROSS
| | |-—NET
| |-ALARM MODE u
| | |-—NORMAL
| | |-—LATCHED
| |-ALARM THRESHOLDS u
| | |-ALARM LOW———
| | |-ALARM HIGH———
| |-ALARM TRIGGER u
| | |-—DISABLED
| | |-—OUTSIDE LIMITS
| | |
| | |-—INSIDE LIMITS
| | |
| | |-—ABOVE HIGH
| | |
| | |-—BELOW HIGH
| | |
| | |-—ABOVE LOW
| | |
| | |-—BELOW LOW
| |
Select the next Calibration Range (only for non-TEDS devices)
Select the next Display Mode
Increase or decrease the number of decimal places displayed for
all displayed values using the same units as the main display
No action
Select this item to choose the action when the left and right keys
are pressed and released after around one second (when not in the
menu)
No action
Select the next Calibration Range (only for non TEDS devices)
Select the next Display Mode
Increase or decrease the number of decimal places displayed for
all displayed values using the same units as the main display
Allows setting of time and date
Display time and date
Display and edit the date
Display and edit the time
Displays information about this product
Configure settings for the global alarm
Only appears when a latched alarm state is present. Click to retry
alarm state
Select the source value the alarm is based on.
Base Alarm on Gross value
Base Alarm on Net value
Select the Alarm Mode
Alarm only active while value matches trigger criteria
Alarm remains active until reset once triggered
Set the alarm low and high thresholds
Edit Low Alarm value
Edit High Alarm value
Select how the alarm is triggered
The Alarm is disabled
Alarm is triggered when the source value is below the Alarm Low
level or above the Alarm High Level
Alarm is triggered when the source value is higher than the Alarm
Low level and lower than the Alarm High Level
Alarm is triggered when the source value is above the Alarm High
level
Alarm is triggered when the source value is below the Alarm High
level
Alarm is triggered when the source value is above the Alarm Low
level
Alarm is triggered when the source value is below the Alarm Low
level
Model 7561-PSDS User Manual |
Issue A
008-0752-00
sps.honeywell.com/ast
| 22