Setting Stages Of Thermostat Control - Honeywell Hometronic HCM 200d Operation

Hometronic manager
Hide thumbs Also See for Hometronic HCM 200d:
Table of Contents

Advertisement

Adaptation
Adapting thermostat control

Setting stages of thermostat control

You specify the offset between the actual temperature and the
room setpoint for the switching points of the thermostat control.
You can set the offset from –10 °C to +10 °C.
Example: To cool the living room, Stage 1 of the thermostat con-
trol is to be switched off with a deviation of –3 °C and switched
on with a deviation of +1.5 °C.
Change to the "Settings" submenu as described on Page 54.
Turn
"Room control Parameters" is
selected.
Press the Dial button.
The list of all room names ap-
pears in the display:
Press the Dial button.
The offset temperatures of the
individual stages appear in the
display.
Turn the Dial button until the
switch-off offset of Stage 1 is
selected.
Press the Dial button.
Turn the Dial button until the
desired offset is displayed.
Press the Dial button.
The following text is displayed:
90
the
Dial
button
until
SENSOR FUNCTION
SUMMER TIME
PARAMETERS
ROOM CONTROL PARAM
LIVING
DINING
KITCHEN
SLEEPING
LIVING
Stage 1 OFF
Stage 1 ON
Stage 2 OFF
LIVING
Stage 1 OFF
Stage 1 ON
Stage 2 OFF
LIVING
Stage 1 OFF
Stage 1 ON
Stage 2 OFF
LIVING
Stage 1 OFF
Stage 1 ON
Stage 2 OFF
-1.0 C
0.0 C
1.0 C
-1.0 C
0.0 C
1.0 C
-3.0 C
0.0 C
1.0 C
-3.0 C
0.0 C
1.0 C