Hometronic – An Overview
Important information on: Operating modes and functions

Temperature control with HCM 200d and storey controller

A setpoint adjuster HCW 22 is assigned to the HCM 200d and to
a storey controller HCE for the same room.
(1) Hometronic Manager HCM 200d
(2) Setpoint adjuster HCW 22
(3) Storey controller HCE 60
(4) Radiator controller HR 50
Example:
1. A setpoint of 20 °C is specified in the HCM 200d. The set-
point adjuster measures a current temperature of 18 °C. Fur-
thermore, an offset of +3 °C is set at the adjustment dial.
2. The setpoint adjuster transmits the current temperature
(18 °C) and the offset (+3 °C) to the storey controller and the
HCM 200d.
3. The HCM 200d transmits...
20
the current temperature (18 °C) and the sum of the set-
point and the offset (23 °C) to the radiator controller,
the current temperature (18 °C) and the sum of the set-
point and the offset (23 °C) to the radiator controller.