Setting up remote access to HR 50

This chapter explains how to regulate the radiator controller
HR 50 via the setpoint adjuster HCW 22 or the temperature sen-
sor HCF 22.
If you would like to regulate a radiator controller via a setpoint
adjuster, both devices must be assigned to the same room.
Example: Set up remote access of an HR 50 via a setpoint ad-
juster HCW 22 in the living room.
Assign the radiator controller HR 50 to the "living" room at the
Hometronic Manager as described in the Chapter entitled
"Binding" of the operating instructions of the HR 50.
Assign the setpoint adjuster HCW 22 to the "living" room at
the Hometronic Manager as described in the Chapter entitled
"Binding" of the operating instructions of the HCW 22.
For information on regulating the radiator controller HR 50 via the
Hometronic Manager, read Chapter "Activating Manual mode
from Page 33.

Remote access to radiator controller HR 50

The radiator controller HR 50 only receives data from the Home-
tronic Manager HCM 200d. To regulate the radiator controller
HR 50 via a setpoint adjuster HCW 22 or a temperature sensor
HCF 22, the devices must be assigned to the same room at the
Hometronic Manager HCM 200d.
With setpoint adjuster HCW 22
The setpoint adjuster HCW 22 transmits the room temperature
and offset to the Hometronic Manager. The HCM 200d displays
the room temperature and offset (in the form of an arrow).
The HCM 200d transmits the resulting setpoint (setpoint plus its
own offset plus offset of setpoint adjuster) to the radiator control-
ler.
Operation
Radiator controller HR 50
45